• When 6” diameter decorative pipe is installed to |
cover the venting any Listed Flexible Gas liner must |
Venting through a Masonry or Prefabricated Manufactured Chimney
be connected directly to the stove’s draft hood. |
• Use of single wall connector pipe as a vent is |
prohibited for use with the GF300 Allagash |
stove. |
• A firestop is required at every floor. |
• Any venting that is exposed above the first floor, |
regardless of attic space or living space, must be |
enclosed. Always maintain the required clearance |
from all sides of the vertical vent system according |
to manufacture. |
Top sealing achor plate
Type B vent or
Listed Flexible Gas
Liner.
Storm collar required
Listed
termination cap required
• Installation of any components not manufactured or |
approved by Jøtul or failure to meet all clearance |
requirements will void all warranties and could result |
in property damage, bodily injury, or serious fire. |
• Never modify any venting component, or use any |
damaged venting product. |
• THE GAS APPLIANCE AND VENT SYSTEM MUST BE |
VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD- |
ING, AND NEVER ATTACHED TO A CHIMNEY SERV- |
ING A SOLID FUEL OR GAS BURNING APPLIANCES. |
• BE SURE TO MAINTAIN THE PROPER CLEARANCES TO |
COMBUSTIBLES AS DEFINED IN THIS MANUAL AND |
IN THE INSTRUCTIONS PROVIDED WITH EACH |
VENTING COMPONENT. |
• When installing at an altitude above 2000’ the |
minimum vertical rise becomes 12’ from the draft |
hood. |
NOTE:
A chimney system located outside the building envelope may be subject to downdrafting and/or flow reversal.
All
Use of Type B vent liner within outside chimneys is recommended to help keep the gases warm and stabilize draft.
Max. Height 35 ft. Min. Height 7 ft.
Always
maintain the
proper
clearance to mantel and trim
Maximum offset is 4 ft.
Recommended
damper sealing plate to seal flue chamber to prevent heat loss
WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS DIAGRAM OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.
Figure 6. GF 300 BV venting through a masonry chimney.
9