ENGLISH
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
■Operating command
Type |
| Command | Description | |
|
|
| ||
Connection check | PC→This unit: 21 89 01 00 00 0A | Connection check | ||
This unit→PC: 06 89 01 00 00 0A | ||||
|
| |||
Power (On) | PC→This unit: 21 89 01 50 57 31 0A | When power is turned on from standby | ||
This unit→PC: 06 89 01 50 57 0A | mode | |||
| ||||
Power (Off) | PC→This unit: 21 89 01 50 57 30 0A | When power is turned off (standby mode) | ||
This unit→PC: 06 89 01 50 57 0A | from | |||
| ||||
Input (COMP.) | PC→This unit: 21 | 89 01 49 50 32 0A | When video input is set to component | |
This unit→PC: 06 | 89 01 49 50 0A | |||
|
| |||
Remote Control | PC→This unit: 21 | 89 01 52 43 37 33 32 45 0A | When the same operation as pressing | |
the [MENU] button on the remote control | ||||
(MENU) | This unit→PC: 06 | 89 01 52 43 0A | ||
is made | ||||
|
|
|
■Reference command
Type |
| Command |
| Description | ||||
|
|
| ||||||
| PC→This unit: 3F 89 01 50 57 0A | When information of | ||||||
Power (On) | This unit→PC: 06 89 | 01 | 50 | 57 0A | ||||
acquired | ||||||||
| This unit→PC: 40 | 89 | 01 | 50 | 57 | 31 0A | ||
|
| |||||||
| PC→This unit: 3F 89 01 49 50 0A | When information of | ||||||
Input | This unit→PC: 06 | 89 | 01 | 49 | 50 | 0A | ||
acquired | ||||||||
| This unit→PC: 40 | 89 | 01 | 49 | 50 | 30 0A | ||
|
|
Getting Started
Preparation
Basic Operation
Settings
Troubleshooting
Others
55