Troubleshooting (cont.)

Problems

Points to be checked

Measures (Remedy)

Reference

pages

 

 

 

 

 

 

 

Wrong picture

Has the picture position, size,

Adjust the picture size (H. SIZE, V. SIZE) or

 

position, wrong

distortion, or tilt been changed?

position (H. POSITION, V. POSITION) in “SIZE/

 

picture size

 

POSI. ADJ.”

 

 

 

Adjust the picture distortion (PARALLELOGRAM,

 

 

 

TRAPEZOID) or tilt (ROTATION) in

17

 

 

“DISTORTION ADJ.”

 

 

 

It may not be possible to expand the picture due

 

 

 

to the selected input mode. In this case,

 

 

 

adjustment is impossible.

 

 

 

 

 

 

Has the SCAN SIZE button been

Press the SCAN SIZE button to invalidate the

5

 

pressed?

setting.

 

 

 

 

 

 

Some items do

The items which are not available for

Change the input or the input signal.

 

not appear on the

the current input (input unit) or the

 

menu

current input signal do not appear on

 

 

 

 

the menu.

 

 

 

 

 

 

Front panel

Has the CONTROL LOCK function

Set the CONTROL LOCK function to “OFF.”

18

buttons do not

been set to “ON”?

 

 

 

function

Has the monitor’s setting been

Change the setting of the external control so that

 

 

changed to enable control by the

the monitor can be operated by the buttons on

19, 20

 

external control connected to the

the front panel.

 

 

 

REMOTE terminal?

 

 

 

 

 

 

The following are not malfunctions:

• About CRT tube reflection (when Zoom mode is used.)

The screen might appear as brownish white. This is due to a reflection of part of the image on the CRT caused by certain signal sources, and it is not a malfunction.

• When a bright still image (such as a white cloth) is displayed for a long period, it may appear to be colored. This is due to the structure of the cathode ray tube and will disappear when another image is displayed.

• You may sometimes experience a mild electric shock when you touch the picture tube. This phenomenon is due to a normal buildup of static electricity on the CRT and is not harmful.

• The monitor emits a strange sound when the room temperature changes suddenly. This is only a problem if an abnormality appears on the screen as well.

• If two or more monitors are placed close each other, their images may shake or be distorted. This phenomenon is due to mutual interference; it is not a malfunction. Move the monitors away from each other until the interference disappears or turn the power off on any monitor that is not being used.

￿Self-check Indications

When the screen goes blank, and one or more of the INPUT SELECT A through D lamps on the front control panel start

blinking...

This monitor has a self-check function, which allows it to detect malfunctions and alert you. This makes troubleshooting easier. Whenever a problem occurs, a combination of “self-check indicators” (INPUT SELECT A through D lamps) will blink and the monitor’s power automatically turns off. If this happens, follow the steps below and contact your dealer to resolve the problem.

1.Check which indicators are blinking.

2.Turn off the main power switch on the back of the monitor.

3.Disconnect the Power Cord from the AC outlet.

4.Contact your dealer with the information about which indicators are blinking.

NOTE:

If you turn on the monitor’s power immediately after turning it off (or after a short-term power failure), the self-check indicators may blink, and no image may be displayed.

When this happens, turn off the power, and wait at least 10 seconds before turning it on again. If the self-check indicators have stopped blinking, you can use the monitor as usual.

22