How to Use External Control

7 About the external control

This monitor has two external control terminals as follows:

RS-232C terminal: For operation using this terminal, consult your dealer.

RS-485 terminals: You can select the external control system in “REMOTE SYSTEM” on the set-up menu (see “CNT. RJ45 OUT” and “CNT. RJ45 IN” on page 25).

(1)Serial communication: Controls the monitor by a personal computer or a dedicated controller (see page 32).

(2) IR OUT system:

Controls other equipment by using the remote control supplied with this monitor.

(3)MAKE (make contact system): Controls the function by short-circuiting the corresponding pin terminal to the GND pin terminal, or disconnecting (opening) it (see page 33).

(4)TRIG. (trigger system): Controls the function by inputting the pulse signal instantaneously to the corresponding pin terminal (see page 33).

Set the input/output terminals correctly according to the system you use (see “REMOTE SYSTEM” on page 25).

Control system

“REMOTE IN SEL.” setting

“CNT. RJ45 OUT” setting

“CNT. RJ45 IN” setting

RS-232C

D-sub9

RS485

Any

Serial communication

RJ-45*

RS485

RS485

 

 

 

 

 

D-sub9*

RS485

Any

 

 

 

 

IR OUT system

Any

IR OUT

Any

MAKE system

RJ-45

RS485

MAKE

 

 

 

 

TRIG. system

RJ-45

RS485

TRIG.

*For the monitor connected to the external control equipment, set “REMOTE IN SEL.” according to the actual connection. Set other monitors by following the setting of the serial communication with “REMOTE IN SEL.” set to “RJ-45” in the table above.

NOTE

Control priority is as follows:

MAKE or TRIG. (trigger) system > RS-485 system > Buttons on the remote control or the main unit

While the Control Lock is in use, you can use external control.

<Serial communication>

Several monitors can be controlled by connecting their RS-485 IN and OUT terminals. See also page 32.

Personal computer or a dedicated controller

RS-485 IN or

RS-485

RS-485 IN

RS-485 OUT

RS-485 IN

RS-485 OUT

RS-232C

OUT

 

 

 

 

<IR OUT system>

Control signals from the remote control are sent to external equipment via the RS-485 OUT terminal.

Karaoke component, etc.

RS-485 OUT

Remote control (supplied)

<MAKE/TRIG. system>

You can control the monitor by a personal computer or a dedicated controller*. See also page 33.

*External control unit is not commercially available. Consult your dealer if you need a dedicated controller.

31