60EN

TROUBLESHOOTING(cont.)

 

SYMPTOM

 

 

POSSIBLE CAUSES

 

32.

The charge indicator on

32.

•The temperature of the

 

 

the AC Power Adapter/

 

 

battery is extremely high/

 

 

Charger does not light.

 

 

low.

 

 

 

 

 

•Charging is difficult in

 

 

 

 

 

places subject to extremely

 

 

 

 

 

high/low temperatures.

 

 

 

 

 

 

33.

The recording mode

33.

•This occurs when recording

 

 

indicator “LP” blinks.

 

 

in the LP mode is not

 

 

 

 

 

available. After the indicator

 

 

 

 

 

blinks, the recording mode

 

 

 

 

 

switches to “SP” and

 

 

 

 

 

recording goes on.

 

 

 

 

 

 

34.

Picture does not appear in

34.

•The lens cover is closed.

 

 

the viewfinder.

 

 

 

 

 

 

 

 

 

35.

When the image is printed

35.

•This is not a malfunction.

 

 

from the printer, a black

 

 

 

 

 

bar appears at the bottom

 

 

 

 

 

of the screen.

 

 

 

 

36.The power lamp blinks. 36. •The camcorder was turned on when the battery power was almost gone.

CORRECTIVE ACTION

32.•To protect the battery, it is recommended to charge it in places with a temperature

of 10°C to 35°C (50°F to 95°F) (pg. 67).

33.

————

34.•Open the lens cover (pg. 16).

35.•By recording with Picture

Stabilizer activated

(pg. 18) this can be avoided.

36.•Replace with a charged battery pack (pg. 8).

Page 60
Image 60
JVC GR-DVA1, LYT0217-001A manual 60 EN, Possible Causes