7. SHOOTING OPERATION
RET button
* This function does not work when the GY-DV500 is in
the save mode or stop mode.
* During recording check, the following indications will
appear if the error rate increases due to head clogging,
etc.
"RF" appears on the display panel.
"HEAD CLOG" appears on the counter display.
"VTR WARNING (HEAD)" appears in the viewfinder.
The recording check function is only valid in the standby mode
(VTR switch set to STBY).
In the record-pause mode, approximately 2 seconds of the last
recorded portion can be played back.
The recorded contents can be checked in the viewfinder or
on a monitor connected to the MONITOR OUT orY/C OUT
connectors.
In the viewfinder or on the monitor connected to the
MONITOR OUT orY/C OUT connectors, the video image
from the VCR section is output.
1'. In the record-pause mode, press the RET button on the
camera lens section.
The tape is slightly rewound and played back for
approximately 2 seconds.
After playback is finished, the tape returns to the position
at which the RET button is pressed and the record-pause
mode resumes.
When the RET button is kept pressed, the tape is rewound
and played back for approximately 10 seconds at maximum.
While the RET button is pressed, the record-mode is not
entered even if the VTR trigger button is pressed.