14. OTHERS
In the case of troubles occurring during operation of the GY-DV500, it performs a self-test to identify the cause and displays the
result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which
indicates the details. Depending on the status of the GY-DV500 at this time, indications may also appear on the LCD display, the
WARNING indicator may activate and the alarm tone may be generated.
tn the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)",
"VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some
of the other error codes are displayed.
WARNING indicator
Main code
Sub-code
WARNING indicator
Red, blinking
Red, blinking
Alarm Tone
Continuous
Intermittent
Display
"Error code"
"Error code"
plus
"AUTO OFF"
"DEW"
GY-DV500 Operation
Automatically ejects the cassette. It can be inserted again.
Automatically stops operation or ejects the cassette.
(Auto OFF) * The GY-DV500 does not accept any operation.
Dew condensation inside the unit.
The GY-DV500 does not accept any operation until the DEW indicator
disappears from the display.
* In the Auto OFF status, it is impossible to operate the GY-
DV500. This condition can be cancelled by switching the
POWER switch OFF and then switching it ON again. If the
same problem occurs again after the power is turned ON,
there may be something wrong with the GY-DV500. Please
consult the person in charge of professional video equipment
at your nearest JVC-authorized service agent.
The GY-DV500 is a microcomputer-controlled piece of
equipment, which may malfunction due to external noise
or interference. In this case, set the POWER switch to OFF,
remove the lithium backup battery, and then set the
POWER switch to ON again after a few minutes.
E-89