12. SETUP MENU
Item
COLOR
MATRIX
GAMMA
SKIN COLOR
ADJUST
PAGE BACK
Function, Operation
Sets the colour matrix
OFF...... Deactivates the colour matrix function
ON
.......
The colour reproducibility is enhanced, but noise
increases.
CAUTION:
During the LOLUX operation, COLOR MATRIX is fixed to the OFF
setting and "FIX" is displayed.
Correction of the gamma curve to decide the reproducibility of black color.
To enhance the black colour reproducibility. However, halftones will be
lost for white section
............... Increase the number
When reproducibility of the black colour is not so important
............... Decrease the number
CAUTION:
During LOLUX operation, "FIX" is displayed because GAMMA is fixed
at the MIN value.
Pressing the SHUTTER dial once when the cursor is at this position
switches the screen to display the SKIN COLOR ADJUST screen.
The PROCESS MENU returns when the SHUTTER dial is pressed with
the cursor at this position.
Variation Range
ON
OFF
MAX (8)
7
17
gradations
to
NORMAL (0)
to
-7
MIN (-8)
"
Initial Setting
ON
NORMAL
Item
SKIN
COLOUR
DETECT
SKIN COLOR
RANGE
PAGE BACK
Function, Operation
Sets whether it is possible to change the colour used by the Skin Detail
function.
EXECUTE ...... Choose this setting to allow detection of the colour used
by the Skin Detail function.
STOP ............. Choose this setting to stop detection of the colour used
by the Skin Detail function.
us- See "Using the Skin Detail Function" on page 84.
The setting of this item can only be changed when the SKIN COLOR
DETECT item is set to EXECUTE.
This setting is for adjusting the skin colour range where Skin Detail
functions. (When this item is selected, the area where the Skin Detail
function is applicable is indicated by zebra patterns on the screen.)
While viewing the zebra pattern range, perform the adjustment.
Increasing the range Increase the number
Increasing the range . ...... Decrease the number
The ADVANCED PROCESS MENU returns when the SHUTTER dial is
pressed with the cursor at this position.
Variation Range
STOP
EXECUTE
WIDE
+19
(33 gradations)
to
NORMAL
to
-11
NARROW
Initial Setting
STOP
NORMAL
E-75