Connections & Installation
Point-to-Point Communication System
The following illustration shows a system in which a remote control unit (or a similar piece of equipment) controls a single camera.
Video out
Control signal cable
AC 24 V power supply
( CAUTION
Switch 4 : OFF (Point to Point) Switch 8 : ON (Terminated 110Ω)
Observe the following points when connecting components together:
•Turn all the components off before proceeding.
•Read the instruction manuals of all components before proceeding.
Monitor
Controller
Cable connections ☞ P. 16
(Terminal side of the Ceiling Mount)
Control signal cable
| To controller |
Coaxial cable |
|
| To monitor |
| To the AC 24V power supply |
Power cable | ( CAUTION |
Switch settings ☞ P. 14
(Setting switches are on the side of the Ceiling Mount)
Setting not required
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
F
F
O
Switch 1 : Invalid (Set to OFF)
Switch 2 :
Switch 4 : OFF
Switch 5 : Configure in accordance with the requirements of the controller communication system.
Switch 7 : Invalid (Set to OFF)
Switch 8 : ON
MEMO
If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms of magnetism, for example near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from noise and colors may be affected.
An optionally available controller is required to use a
CAUTIONS
●The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)
●In order to prevent an excessive current flow through the power supply wire or camera due to a short circuit, a fuse must be installed in the power supply line.
12