Item

 

 

 

 

 

 

 

 

 

Function & Setting

Initial Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM INPUT ..

(Continued)

 

 

POLARITY

Sets the polarity of the alarm signal inputs.

MAKE

 

 

MAKE : Alarm signals are transmitted when point of contact is made.

 

 

 

BREAK : Alarm signals are transmitted when contact is broken.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When an item for the B&W is set to the ALARM 1 to 4, it is set to the MAKE mode even if

 

 

 

 

 

“BREAK” is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DURATION

Sets the length of an alarm operation once an alarm signal has been transmitted.

5s

 

 

(Unit:second)

 

 

 

Setting values : 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s or 60s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

This item is invalid with the system using the RM-P2580. When using the RM-P2580, use

 

 

 

 

 

item “ALARM TIME” instead.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIORITY

Sets whether or not manual operation is accepted in case an alarm input is recog-

ALARM

 

 

nized during manual operation of the camera.

 

 

 

ALARM : Manual operation is not accepted when there is an alarm input.

 

 

 

 

 

 

 

 

 

 

 

(Priority on alarm)

 

 

 

MANUAL : Manual operation is accepted even when there is an alarm input.

 

 

 

 

 

 

 

 

 

 

 

(Priority on manual)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

This item is invalid with a system using the RM-P2580. With this system, the ALARM input

 

 

 

 

 

is permanently given the priority.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUTPUT ..

Sets the configuration of the alarm output terminals on the Ceiling Mount.

 

ALARM OUT1

Sets the configuration of the Alarm output 1 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Since the ALARM OUT 1 terminal employs a mechanical relay, its operating sound may

 

 

 

 

 

 

 

 

seem noisy in a quiet environment. In this case, use the ALARM OUT 2 or 3 terminal

 

 

 

 

 

 

 

 

instead.

 

 

 

 

 

 

 

 

 

 

 

Sine the ALARM OUT 1 terminal employs a mechanical relay, the service life of the relay

 

 

 

 

 

 

 

 

may be shortened if signals causing an alarm (motion detect signal, etc.) are applied fre-

 

 

 

 

 

 

 

 

quently. The service life of a relay is 200,000 times of operation. The relay is a consumable

 

 

 

 

 

 

 

 

part and a replacement is chargeable even before the termination of the warranty period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUT2

Sets the configuration of the Alarm output 2 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUT3

Sets the configuration of the Alarm output 3 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 