| Item |
|
|
|
|
|
|
|
|
| Function & Setting | Initial Value | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
ALARM INPUT .. | (Continued) |
| ||||||||||||
| POLARITY | Sets the polarity of the alarm signal inputs. | MAKE | |||||||||||
|
| MAKE : Alarm signals are transmitted when point of contact is made. |
| |||||||||||
|
| BREAK : Alarm signals are transmitted when contact is broken. |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| MEMO |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| When an item for the B&W is set to the ALARM 1 to 4, it is set to the MAKE mode even if |
| |||||||||
|
|
|
| “BREAK” is displayed. |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| DURATION | Sets the length of an alarm operation once an alarm signal has been transmitted. | 5s | |||||||||||
|
| (Unit:second) |
| |||||||||||
|
| Setting values : 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s or 60s |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| CAUTION |
| |||||||
|
|
|
| This item is invalid with the system using the |
| |||||||||
|
|
|
| item “ALARM TIME” instead. |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| PRIORITY | Sets whether or not manual operation is accepted in case an alarm input is recog- | ALARM | |||||||||||
|
| nized during manual operation of the camera. |
| |||||||||||
|
| ALARM : Manual operation is not accepted when there is an alarm input. |
| |||||||||||
|
|
|
|
|
|
|
|
|
| (Priority on alarm) |
| |||
|
| MANUAL : Manual operation is accepted even when there is an alarm input. |
| |||||||||||
|
|
|
|
|
|
|
|
|
| (Priority on manual) |
| |||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| CAUTION |
| |||||||
|
|
|
| This item is invalid with a system using the |
| |||||||||
|
|
|
| is permanently given the priority. |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
ALARM OUTPUT .. | Sets the configuration of the alarm output terminals on the Ceiling Mount. | – | ||||||||||||
| ALARM OUT1 | Sets the configuration of the Alarm output 1 terminal. | ALARM | |||||||||||
|
| OFF | : Does not output an alarm signal. |
| ||||||||||
|
| ALARM | : Alarm signal is output upon input of motion detection or an alarm signal. |
| ||||||||||
|
| B&W | : Alarm signal is output when the camera enters the B&W mode. |
| ||||||||||
|
| PRESET : Alarm signal is output when a camera moves to a preset position. |
| |||||||||||
|
| AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This |
| |||||||||||
|
|
|
|
|
|
|
|
|
| is variable depending on the remote control unit in use.) |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| MEMO |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| ● Since the ALARM OUT 1 terminal employs a mechanical relay, its operating sound may |
| |||||||||
|
|
|
|
|
|
| seem noisy in a quiet environment. In this case, use the ALARM OUT 2 or 3 terminal |
| ||||||
|
|
|
|
|
|
| instead. |
|
|
|
|
|
|
|
|
|
|
| ● Sine the ALARM OUT 1 terminal employs a mechanical relay, the service life of the relay |
| |||||||||
|
|
|
|
|
|
| may be shortened if signals causing an alarm (motion detect signal, etc.) are applied fre- |
| ||||||
|
|
|
|
|
|
| quently. The service life of a relay is 200,000 times of operation. The relay is a consumable |
| ||||||
|
|
|
|
|
|
| part and a replacement is chargeable even before the termination of the warranty period. |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| ALARM OUT2 | Sets the configuration of the Alarm output 2 terminal. | ALARM | |||||||||||
|
| OFF | : Does not output an alarm signal. |
| ||||||||||
|
| ALARM | : Alarm signal is output upon input of motion detection or an alarm signal. |
| ||||||||||
|
| B&W | : Alarm signal is output when the camera enters the B&W mode. |
| ||||||||||
|
| PRESET : Alarm signal is output when a camera moves to a preset position. |
| |||||||||||
|
| AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This |
| |||||||||||
|
|
|
|
|
|
|
|
|
| is variable depending on the remote control unit in use.) |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| ALARM OUT3 | Sets the configuration of the Alarm output 3 terminal. | ALARM | |||||||||||
|
| OFF | : Does not output an alarm signal. |
| ||||||||||
|
| ALARM | : Alarm signal is output upon input of motion detection or an alarm signal. |
| ||||||||||
|
| B&W | : Alarm signal is output when the camera enters the B&W mode. |
| ||||||||||
|
| PRESET : Alarm signal is output when a camera moves to a preset position. |
| |||||||||||
|
| AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This |
| |||||||||||
|
|
|
|
|
|
|
|
|
| is variable depending on the remote control unit in use.) |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25