- 7
ÎConnect the water supply hose to the
respective water inlet (arrow).
ÎOpen the lock on the appliance cover
and swivel the appliance cover up-
wards.
ÎSwivel the latch of the appliance hood
upwards to keep it from shutting inad-
vertently.
ÎCheck the water filter for contamination,
clean/replace if required.
ÎCheck the position of the ball tap in the
antifreeze/water tank, set to the water
tank on the right.
ÎClose the drain tap of the water tank.
ÎSwitch on the battery main switch.
ÎTilt the safety latch of the appliance
hood toward the bottom.
ÎTilt the appliance hood downward and
lock it.
ÎOpen the door to the operating panel
and switch on the ignition via the keys-
witch.
If the tank level is low, the water will be sup-
plied
Note
The appliance can only be operated with
the appliance hood closed. The appliance
will switch off when the appliance hood is
opened.
ÎRelease emergency-stop button by
turning.
ÎOpen the operating panel door.
ÎTurn the key switch to the right.
The control voltage is switch on and the dis-
play shows the operating status.
At low ambient temperatures, the preheat-
ing process will start automatically. The re-
spective message is shown on the display.
ÎPress the F2 key to start the motor.
Motor runs warm.
During the warm up time, the display will
show the clock symbol.
After the warm up time, the appliance will
be ready for high pressure operation.
ÎConnect the high pressure hose, gun
and the spray pipe without nozzle as
described in chapter "Startup".
ÎActivate the gun about 30 to 40 sec-
onds until a continuous water jet is emit-
ted from the spray pipe.
ÎSwitch off the motor.
ÎInstall the nozzle as described in the
chapter "Connecting the nozzle".
Note
The water pressure can be changed right
after startup with the key switch as well as
during operation.
ÎAdjust the water pressure using the F5
and F4 keys "Increase/reduce water
pressure".
The water pressure can be changed in
increments of 5 MPa (50 bar).
The set water pressure has been reached.
ÎStep 1: Press F6 key.
ÎStep 2: Press F4 key.

Start the engine

Ventilating the high pressure system

Settings

Adjust the water pressure
Adjust the brightness and contrast of
the display
9EN