Operating instructions | KM 100/100 R / KM 100/100 R P | English |
Machine components
1. Unit cover
2.Debris container (bilateral)
3.
4.Roller
5.Side brush
Before first operating
The sweeper has an electric drive. The machine can be pushed only if the trigger is pulled away from the wheel.
(See chapter: Moving the sweeper without its own drive)
Open/close unit cover
Open unit cover
!Swivel unit cover upwards at the provided handle grip
When opened the unit cover is secured by a stay bar.
!Insert the stay bar into the adapter at the suction turbine
!To close the unit cover pull the stay bar out of the holder and engage it in the bracket in the unit cover
Operating sweeping machine without automotive power
Danger!
Prior to manually releasing the parking brake the sweeper is to be secured against movement.
After the parking brake is released the sweeper coasts unbraked.
!Pull the brake lever away from the wheel and hold it tight in this
position
—The function of the parking brake is thus out of action and the sweeper can be pushed
Unloading instructions
Warning!
Generally it is not permitted for the parking brake to be released when loading the machine.
—The machine was secured on a pallet with stretch belts or ropes
for safe transport. Proceed as follows when unloading:
!Cut the plastic packing tape and remove the film.
!Remove the blocks for securing the wheels and drive the machine off the pallet using a suitable ramp.
Warning!
Do not use a fork lifter for unloading; the machine can be damaged by it.
!Pull stay bar out of the bracket
21