KMR 1250 B | User Instructions | English |
Replacing fuses
nPark the sweeper and switch off the engine.
nOpen the unit cover.
n Replace a defective fuse with one of the same current value.
Note:
Repeated defects of the same fuse indicate a technical fault in the electrical system. Please call Kärcher Customer Service.
Replacing the dust filters
The dust filters should be inspected for damage every 50 operating hours.
A significant
n Raise the hopper half way 1.
nRelease the catches on the filter box 2.
n Swivel the filter box forwards and lift it off 3.
nOpen out the handle, pull it outwards and turn it through 90º (make sure it engages) 4.
n Remove the filter cartridge 5.
n Insert a new filter cartridge (pins should fit into the holes) 6.
nSet the handle back to its original position and lock it.
Make sure the filter is correctly seated.
nMount the filter box and engage the catches.
49