4.4.4.LNB settings
(1)LNB
{ON} | Standard setting |
{OFF} | Operation without LNB signal (e.g. on special systems with several subscribers) |
(2)In standby
{OFF} Standard setting
Attention! | Only use the setting {OFF} for individual systems, otherwise the receiver |
| supplies the LNB with power even in standby. The power consumption |
| of the receiver can increase from typically 2 watts to up to 10 watts in |
| standby. |
{ON} In standby, the LNB voltage remains switched on, e.g. for supplying power to a system with several subscribers.
4.4.5.DiSEqC (Digital Satellite Equipment Control)
In the DiSEqC menu, the control signals must be set according to the requirements of your satellite system.
(1)22 kHz signal
{OFF} | 22 kHz not active |
{High/Low} | 22 kHz switches between high and low band |
{Pos. A/B} | 22 kHz switches between 2 satellites |
(2)Tone burst
| {OFF} |
|
| {High/Low} | activates the tone burst depending on the receiving frequency |
| {Pos. A/B} | selects the orbit position 1/3 or 2/4 |
| {Opt. A/B} | switches between the orbit position 1/2 and 3/4 |
(3) | DiSEqC |
|
| {OFF} , {ON} | Select {ON}, when you operate the receiver on a DiSEqC compatible satellite |
|
| receiving system. |
(4)DiSEqC repeat (used for cascaded switching matrices)
{OFF} | no repetition of the DiSEqC signal | ||
{ | 1 | } | the DiSEqC signal is repeated 1 time. |
{ | 2 | } | the DiSEqC signal is repeated 2 times. |
(5)UFO
„UFO mini“ and „UFO micro“ are specific SAT systems from the company Kathrein. Please take the required parameters from the respective operating manuals.
(1) | UFO mini | {OFF } / {ON} |
(2) | Remote Freq. | {XXXX} |
(3) | UFO micro | {OFF} / {ON} |
With the [M] button, access the main menu. The desired submenus are activated by pressing the numerical buttons [1]....[X] or the programme buttons [▼] / [▲]. The selected submenu is then outlined
in colour, and the respective help text appears. This activated submenu is called up by pressing the [OK] button. The other items in the submenu are accessed in the same manner.
By pressing the [E] button, you can skip one step higher in each menu (or exit the menu).
After exiting the menu with the [E] button, the message „save changes“ appears on the screen. Press [OK] to save the changes.
- 17 -