Kathrein UFS 710sw, UFS 710si manual FIRST INSTALLATION Single-cable system Manual

Models: UFS 710si UFS 710sw

1 88
Download 88 pages 48.8 Kb
Page 25
Image 25
Selection “UAS 481” or “EXR 551”

FIRST INSTALLATION: Single-cable system (Manual)

Selection “UAS 481” or “EXR 551”

When the “UAS 481” single-cable feed system is being used, it is essential that the LNB is set to “Wideband”!

When the “EXR 551” single-cable switching matrix is being used, it is essential that the LNB is set to “Universal”!

Transmission channel

Use the  buttons to select a free available transmission channel. A maximum of four transmission channels are available (1400, 1516, 1632 and 1748 MHz).

Test connection

When you have set a free transmission channel, press the  buttons to switch to the “Test connection”

selection field and press the  button. The receiver now tests whether a connection to the single-cable system can be established or not. As soon as the receiver has established a connection to the single-cable system, you will see the following display:

Press the  button to acknowledge this display. Then press the  button. You will be asked whether

you wish to save the changes. Use the  buttons to select “Yes, save changes” and confirm by pressing

the  button. Now press the ! (green) button.

The receiver will automatically display the selection menu for the channel search. Continue by selecting the item (Execute Channel search).

If no connection to the single-cable system could be established, the following display appears:

Check your settings and if necessary call for expert help.