Do not ground to a gas pipe.
Check with a qualified electrician ifyou are not sure the
washer is properly grounded.
Do not have afuse in the neutral orground circuit.
Electrical Shock Hazard
Plug into a grounded 3prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Faimureto follow these instructions can result in death,
fire, or emectrical shock.
A 120 volt, 60 Hz., AC only, 15- or20-amp, fused electrical
supply is required. Atime-delay fuse or circuit breaker is
recommended. Itis recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a
3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded inaccordance with local codes and ordinances. Ifa
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
GROUNDING mNSTRUCTIONS
For a grounded, cord-connected washer:
This washer must be grounded= Hnthe event of a malfunction
or breakdown, grounding wiII reduce the risk of electrical
shock by providing a path of Ieast resistance for electric
current. This washer is equipped with a cord having an
equipment-grounding conductor and a grounding pIug=The
plug must be plugged into an appropriate outlet that is
properly instalIed and grounded in accordance with all local
codes and ordinances=
WARNING: Hmproperconnection of the equipment-
grounding conductor can result in a risk of electric shock=
Check with aqualified electrician or serviceman ifyou are in
doubt as to whether the appliance is properIy grounded=
Do not modify the piug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician=
For a permanently connected washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the appliance=
Ifcodes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.