Installation Instructions (cont'd)

Converting the Lower

Element (cont'd)

2. The convertible element is located behind the lower access

panel of the water heater. Remove the two screws securing the access panel, and remove panel.

5.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

 

6. The buss bar is labeled 5500

W. Place the buss bar

over termi-

 

nals 2 and 3 with the

5500

W visible. Install the

extra screw

3. Remove the insulation block to expose the opening.

provided into terminal

3.

 

 

7. The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.

4.Lower Element: Lift out the tab as shown to unclip the ter- minal cover from the thermostat. The terminal cover can be

removed from the thermostat.

Lift out tab to unclip terminaJ cover from

thermostat

TERMINAL COVER

CLIPPED TO THER-

MOSTAT AT THIS

POINT_

PLASTIC TABS ON

mOTH SIDES OF

TERMINAL COVER HOLD IT IN PLACE.

THERMOSTAT

BRACKET

_:_- TANK

8. Tighten terminals 2 and 3 to ensure proper electrical connection.

AWARNING

Failure to tighten terminal screws can cause a Ere which can result in DEATH, SERIOUS BODILY INJURY, OR

I PROPERTY DAMAGE,

.-._1-ELEMENT

LO_VERTHERMOSTAT--_

11

Page 11
Image 11
Kenmore 153.316252, 153.316554, 153.316555, 153.316455, 153.316754, 153.316355, 153.316654 Converting the Lower Element contd