Safety Precautions

Safety Precautions

•,WARNINGI

Improperinstallation,ad_ alteration,serviceor mainte- I nance can causeDEATH, SERIOUS BODILY INJURY,OR PROPERTYDAMAGE Refer to this manualfor assistanceor

consultyourlocalSearsServiceCont_ for further nformation.

A, WARNING

At thetime ofmanufacturethiswaterheaterwasprovidedwith a combinationtemperature-pressuresreliefvalvecertifiedbya nationallyrecognizedtestinglaboratory that maintainsperiodic inspectionof productionof listedequipmentor materials,as meetingthe requirements for ReliefValvesand AutomaticGas ShutoffDevicesfor Hot Water SupplySystems,and the latest editionof ANSI Z2h22 and the coderequirementsof ASME.If replaced,the valvemustmeet the requirements of localcedes, but not lessthan a combinationtemperatureand pressurerelief valvecertifiedasmeetingthe requirementsfor ReliefValvesand

AutomaticGasShutoffDevicesfor Hot Water SupplySystems, ANSI Z21.22 by a nationallyrecognizedtestinglaboratorythat maintainsperiodic inspectionof productionof listedequipment or materials.

The valvemust be marked with a maximum set pressurenot to exceed the marked hydrostaticworking pressureof the water heater (150 Ibs./sq.in.) and a dischargecapacity not lessthan the water heater input rate as shownon the model rating plate. (Electric heaters, watts dividedby 1000x 3415 equalBTUIHr. rate.)

Yourlocaljurisdictionalauthority,whilemandatingthe useof a temperature-pressurereliefvalvecomplyingwith ANSI Z21.22 and ASME, may require a valvemodeldifferentfrom the one furnishedwith the water heater.

Compliancewith suchlocalrequirementsmust be satisfiedby the installeror end userof the water heaterwith a locallypre- scribedtemperature-pressurereliefvalveinstalledin the desig-

natedopeningin the water heater in placeof the factory for- nishedvalve.

Forsafeoperationof the water heater,the relief valvemustnot beremovedfrom it'sdesigeai_lopeningor plugged.

The temperature-pressurereliefvalvemustbe installeddirectly into the fitting of the water heater designatedfor the relief valve.Fos_on the valvedownwardand providetubingsothat

any dischargewilt exit onlywithin 6 inchesabove,or at any dis- tence belowthe structuralfloor.Be certain that no contactis

madewith anylive electricalpart. The dischargeopeningmust not be blockedor reduced in size under any circumstances.

Excessivelength,over 30 feet,or useof more than fourelbows

can causerestriction and reducethe dischargecapacityof the valve.

No valveor other obstructionisto be placedbetweenthe relief valveand the tank. Do not connecttubingdirectlyto discharge drain unlessa 6" air gap is providedTo. preventbodilyinjury, hazard to llfe, or propertydamage, the relief valve must be allowedto dischargewater in quantitiesshouldcircumstances demand.If the dischargepipe is not connectedto a drain or other suitable means, the water flow may cause property damage.

The DischargePipe:

Must not be smallerin sizethan the outlet pipe sizeof the valve,or haveany reducingcouplingsor other restrictions.

Must not be plugged or blocked.

Must be of material listedfor hot water distribution.

Must be installedso asto allow completedrainageof beth the temperature-pressurereliefvadve,andthe dischargepipe. Mustterminate at an adequatedrain.

Must not haveanyvalvebetween the relief valveandtank.

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned

AWARNINGJ

"OFF". Failure to do this could result in DEATH, SERI-

OUS BOD LY NJURY,OR PROPERTY DAMAGE.

_,WARNING

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- perature which will satisfy space heating, clothes wash- ing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve,

shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufactur- ers instructions for installation of the valves. Before

changingthe factory sett!ng on the thermostat, read the

Temperature Regulation sectionin this manual.

AWARNING

WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equippedfor one type voltage only. Check the rating plate near the bottom accesspanel for the correct voltage. DO NOT use this water heater with any voltage other than the one shownon the model rating plate. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY,OR PROPERTY DAMAGE. If you haveany ques- tions or doubts consultyour electric company.

..... AWARN, ING

INSULATING JACKETS: When installing an external water heater i_Ul_tion jacket on'an electric water heater:

a.DO NOT cover the temperature-pressure relief valve.

b.DO NOT put insulation over the accesscovers or any accessareas.

c.DO NOT cover or remove operating instructions, and

safety related warning labels and materials affixed to the water heater.

_,WARNING

Do not usethis appliance if any part of it hasbeen under water. An electrical short or malfunction could occur.

The water heater shouldbe replaced.

ACAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of

the water heater must be accomplishedin sucha manner that if the tank or anyconnectionsshouldleak, the flow of water will not causedamage to the structure. When such locations cannot be avoided, a suitable drain pan should be installedunder the water heater. Drain pans are avail- able at your local Sears Store. Such a drain pan must be piped to an adequate drain. Under no circumstances is the manufacturer or Sears to be held liable for any water damage in connectionwith this water heater.