Kenmore 153.316654, 153.316554, 153.316555, 153.316455 Service and Adjustment contd, A Caution

Models: 153.316654 153.316454 153.316754 153.316354 153.316554 153.316355 153.316555 153.316252 153.316153 153.316152 153.316755 153.316655 153.316455 153.316253

1 32
Download 32 pages 33.3 Kb
Page 19
Image 19
A CAUTION

Service and Adjustment (cont'd)

TERMINAL

COVER ON

UPPER

THERMOSTAT

7.Disconnect the two wires on the element and unscrew the old element from the tank.

8.Clean the area around the element opening. Remove any

sediment from or around the element opening and inside the tank.

9.If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.

AWARNING

Replacement elements must (I) be the same voltage and

(2)no greater wattage than listed on the model rating p ate affixed to the water heater.

10.A new gasket should be used in all cases to prevent a possi- ble water leak. (See Element Gasket in the Parts Order List

Chart). Place the new element gasket on the thread side of the cleaned or new element and screw into tank, securing tightly using an element wrench.

11.Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of the water heater.

12.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

13.To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the

water heater and the piping.

A CAUTION

Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating ele- ment, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" power

14.Check element for water leaks. If leakage occurs, tighten element or repeat steps 2 and 3, remove element and reposi- tion gasket. Then repeat steps 10 through 14.

15.Reconnect the two wires to the element and then check to

make sure the thermostat remains firmly against the surface of the tank.

19

Page 19
Image 19
Kenmore 153.316654, 153.316554, 153.316555, 153.316455, 153.316754, 153.316355 Service and Adjustment contd, A Caution