Service and Adjustment (cont'd)

Element Cleaning/

Replacement (cont'd)

16.Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.

17.Replace the insulation block so that it completely covers the thermostat and element.

Drain Valve Washer

Replacement

NOTE: For replacement, use a *_2" x ,3/,, x ¼" thick washer

available at your nearest hardware store. For ordering a replacement washer, refer to the "Parts Order List" section.

Before beginning turn "OFF" the electrical power supply to the water heater.

AWARNING

HAZARD OF ELECTRICAL SHOCKI Before removing any access panels or servicing the water heater, make

sure the electrical supply to the water heater is turned "OFF". Failure to do this could result in DEATH, SERI-

OUS BODILY INJURY,OR PROPERTY DAMAGE.

Follow "Draining" instructions. See "Service and Adjustment" section.

18.Replace access panel.

19.Turn "ON" electric power to water heater.

Turning counter clockwise, remove the hex cap below the screw handle.

Remove the washer and put the new one in place.

Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.

Follow !'Filling the Water Heater" instructions in the "Installation Instructions" section.

Check for leaks.

Turn "ON" electric power to the water heater.

_ HANDLE AND

CAP ASSEMBLY

WASHER

Service

Before calling for repair service, read the Start Up Conditions

and Operational Conditions found in the Troubleshooting Guide of this manual.

If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out.

Contact SEARS Repair Services at 1-800-4-MY-HOME