Kenmore 153.316153 Installation Instructions contd, Converting the Lower Element contd

Models: 153.316654 153.316454 153.316754 153.316354 153.316554 153.316355 153.316555 153.316252 153.316153 153.316152 153.316755 153.316655 153.316455 153.316253

1 32
Download 32 pages 33.3 Kb
Page 12
Image 12
Installation Instructions (cont'd)

Installation Instructions (cont'd)

Converting the Lower

Element (cont'd)

9. Replace

terminal

cover on

thermostat making sure that the

12. Complete

wiring to

the

water

heater,

or if completed,

turn

locking

tabs on

the terminal

cover are in place.

"ON"

electric power

to

the

water

heater after filling

the

 

 

 

 

tank

with

water.

 

 

 

 

 

_E,WARNING

Make sure the thermostat is flush against the tank, the terminal cover is in place, and the insulation _sreplaced. Failure to do so can result in DEATH, SERIOUS BODILY NJURY,OR PROPERTY DAMAGE.

10.Replace the insulation block so that it completely covers the thermostat and element.

_, CAUTION

Never use this water heater unlessit is completely full of water. To prevent damage to the tank and heating ele- ment, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" power.

11. Replace the access panel.