Customer ResponSibilities

Customer ResponSibilities

Thank You for purchasinga Sears water heart €. Properly installed and maintained, it should give you years Of trouble free service. If you should decide that you want the new

water heater professionally installed by Sears call the local Sears Service Center or any Sears store. They will arrange for prompt,

quality installation by Sears authorized contractors. Abbreviations Found In This Instruction Manual

I.A.S. - International Approval Services, A Division of CSA A.N.S.I. - American National Standards Institute

N.EP.A. - National Fire Protection Agency

AWARNING

This gas-fired water heater is design certified by the

International Approval Services, A Division of CSA under

American National Standard/CgA Standard for Gas Water

Heaters ANS Z21.10.1 CSA 4.1 (latest edition). The installation must conform with this manual, Local Codes and with the latest edition of the National Fuel Gas Code _SI ZZ23.1.

This publicationis available from your localgovernment o_

public library, gas company, or by writing NFPA, Batterymarch Park, Quincy, MA 02269.

This manual contains instructions for the installation, Opera- tion, and maintemanc¢ 0f the gas-fired water heater. "It also contains warnings through out the manual that you inust read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety.

Since we cannot put everything on the first few pages, READ

THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this

manual; gas company rules; and Local Codes, or in the absence of Local Codes, with the latest edition of the National Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54. This publication is available from your local government or

public library or gas company or by writing NFPA, Batterymarch Park,Quincy, MA 02269.

If after reading this manualTou have any questions or do not understand any portion orthe instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation are very important in preventing death from possible carbon monoxide poisoning and fires.

Examine the location to ensure the water heater complies with the "Facts to Consider about the Location" section in this

manual.

Read the "Safety Precautions" section, pages 2 through 4 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water hearer will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Azchisect, 400 P Street, Sacramento, CA 95814.

Product

Specifications

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

IN INCHES

MODEL

TANK

 

 

RECOVERY RATE

MINIMUM

 

HEIGHTTO

NUMBER

CAPACITY

OF

B.T.U.

GA_. PER HOUR

VENT

 

 

IN GALLONS

 

RATE

@9OOFRISE

PIPE

DIAMETER JACKETTOp

153.330401

40

NATURAL

40,000

46.0

3** or 4"

18"

60"

153.330451

40

NATURAL

40,000

46.0

3" or 4"

18"

60"

153.330501

50

NATURAL

40,000

46.0

3" or 4"

20"

59_"

153.330551

50

NATURAL

40,000

46.0

3" or 4"

20"

59½"

153.330701

75

NATURAL

55,000

59.2

4"

24"

60"

153.330751

75

NATURAL

55,O00

59.2

4"

24"

60"