Installation Instructions
Installation Checklist
BEFORE LIGHTING THE PILOT:
•Check the gas lines for leaks.
a.Use a soapy water solution. DO NOT test for gas leaks usin_a match or open flame.
b.Brusn the soapy water solution on all gas pipes, joints and fittings.
c.Check for bubbling soap. This means you have a leak. Turn "OFF" gas andmake the necessary repairs.
d.Recheck for leaks.
e.Rinse offsoapy solution and wipe dry.
(cont'd)
VENT PIPE TO
OUTDOORS
OR CHIMNEY |
|
HOT | COLD |
UNION | SHUTOFF VALVE |
HOT-•COLD
•Is the new
and piped to an adequate drain? See
•Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the "Installation Instructions" section.
•Is the water heater,completely filled with water? See "Filling" instructions in the Installation Instructions".
•Will a water leak damage anything? See the "Facts to Consider About the Location" section.
Is there proper clearance between the water heater and any-
thing that might catch fire? See the Facts to Consider About the Location" section.
Do you have adequate ventilation so that the water heater
will operate properly? See "Combustion Air and Ventilation" in the "Facts to Consider About the Location" section.
!s the draft hood vent piping properly secured? See "Venting" mstrucuons in the "Installation Instruct'ons' section.
Is there proper clearance between the vent pipe and anything
that might catch on fire? See "Venting" instructions in the "Installation Instructions" section.
Is the vent pipe properly sloped and does the vent terminate
outdoors? See "Venting" instructions in the "Installation
Instructions section.
Do you need to call your gas company to check the gas pipe and its hookup?
CHECK FOR LEAKS
Be sure to check all your gas pipes for leaks before lighting your water heater. Use a soapy water solution, not a match or open flame. Check the factory gas fittings after pilot is lit and gas con- trol knob is still in "PILOT" position. Then, check the fittings
when the main burner is turned "ON". Use a soapy water solu- tion for this, too.
DRAFT
HOOD
PRESSURE
RELIEF VALVE
GAS SUPPLY
DISCHARGE PIPE (Do not cap or plug)
SHUTOFF |
| C_ |
|
VALVE |
|
|
|
DRIP LETGEE'_ mmn_ | _ |
| |
(SEDIMENT _ | R _ | DRAIN VALVE | |
TRAP) | J_ | _ | '(under cover) |
,,NCHA,RGAP
OOR DRAIN._S _1_1O
I I I
15o I . I w 1 wc
MODEL RATING PLATE