![](/images/new-backgrounds/1025635/2563511x1.webp)
Customer Responsibilities
_""inanK You for purchasing a Sears water heater. Properly installed and maintained, it should give you years of trouble free ser- vice. If you should decidethat you want the new water heater profes- sionally installed by Sears call the local Seats Service Center or any
Sears store. They will arrange for prompt, quality,installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual CSA - Canadian Standards Association
ANSI - American National Standards Institute
NFPA - National Fire Protection Association
AWARNING
This
INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANS
Z21.10.1 • CSA 4.1 (latest edition). The installation must conform with this manual, Local Codes and with the latest edition of the National Fuel Gas Code, ANSI Z223.1.
This publication isavailablefrom your local government or lublic library, gas company, or by writing NFPA,
Batterymarch Park, Quincy, MA 02269.
• Read the "Safety Precautions" section, pages 2 and 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate prop-
erly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera- tion, and maintenance of the
Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE WATER HEATER.
•The installation must conform with the instructions in this
manual; sas company rules; and Local Codes, or in the absence of Local Codes, with the latest edition of the National
Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54. This publication is available from your local government or public library or gas company or by writing NFPA, Battetymarch Park, Quincy, MA 02269.
•If after reading this manualyou have any questions or do not
understand any portion of the instructions, call the Sears Service Center.
•Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation are very important in preventing death from possible carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with the "Locating the New Water Heater" section in this manual.
•For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
•Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
Product | Specifications |
|
|
|
| ||
| TANK | TYPE |
| RECOVERY | MINIMUM | DIMENSIONS | IN INCHES |
|
| RATE GALS. | |||||
MODEL NUMBER |
|
| HEIGHTTO | ||||
CAPACITY | OF | B.ZU. | PER HOUR | VENT |
| ||
| IN GALLONS | GAS | RATE | @ 90°F RISE | PIPE* | DIAMETER | JACKET TOP |
153.335816 | 40 | NATURAL | 40,000 | 40.9 | 3" | 18" | 60" |
153.335846 | 40 | PROPANE | 40,000 | 40.9 | 3" | 18" | 60" |
153.335863 | 40 | PROPANE | 40,000 | 40.9 | 3" ' | 18" | 60" |
153.335916 | 50 | NATURAL | 40,000 | 40.9 | y' | 20" | 59_" |
153.335943 | 50 | PROPANE | 40,000 | 40.9 | 3" | 20" | 59_" |
153.335963 | 50 | PROPANE | 40,000 | 40.9 | 3" | 20" | 59V2" |
* Limited usage ofT' vent pipe - see pages 16 and 19.
6