Kenmore 153.335943 Product, Specifications, Customer Responsibilities, Recovery, In Inches, 59V2

Models: 153.335943 153.335863 153.335963 153.335846

1 44
Download 44 pages 60.48 Kb
Page 6
Image 6
Customer Responsibilities

Customer Responsibilities

_""inanK You for purchasing a Sears water heater. Properly installed and maintained, it should give you years of trouble free ser- vice. If you should decidethat you want the new water heater profes- sionally installed by Sears call the local Seats Service Center or any

Sears store. They will arrange for prompt, quality,installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

AWARNING

This gas-fired water heater is design certified by CSA

INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANS

Z21.10.1 • CSA 4.1 (latest edition). The installation must conform with this manual, Local Codes and with the latest edition of the National Fuel Gas Code, ANSI Z223.1.

This publication isavailablefrom your local government or lublic library, gas company, or by writing NFPA,

Batterymarch Park, Quincy, MA 02269.

• Read the "Safety Precautions" section, pages 2 and 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate prop-

erly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, opera- tion, and maintenance of the gas-firedwater heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety.

Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO

INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this

manual; sas company rules; and Local Codes, or in the absence of Local Codes, with the latest edition of the National

Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54. This publication is available from your local government or public library or gas company or by writing NFPA, Battetymarch Park, Quincy, MA 02269.

If after reading this manualyou have any questions or do not

understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation are very important in preventing death from possible carbon monoxide poisoning and fires.

Examine the location to ensure the water heater complies with the "Locating the New Water Heater" section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

Product

Specifications

 

 

 

 

 

TANK

TYPE

 

RECOVERY

MINIMUM

DIMENSIONS

IN INCHES

 

 

RATE GALS.

MODEL NUMBER

 

 

HEIGHTTO

CAPACITY

OF

B.ZU.

PER HOUR

VENT

 

 

IN GALLONS

GAS

RATE

@ 90°F RISE

PIPE*

DIAMETER

JACKET TOP

153.335816

40

NATURAL

40,000

40.9

3"

18"

60"

153.335846

40

PROPANE

40,000

40.9

3"

18"

60"

153.335863

40

PROPANE

40,000

40.9

3" '

18"

60"

153.335916

50

NATURAL

40,000

40.9

y'

20"

59_"

153.335943

50

PROPANE

40,000

40.9

3"

20"

59_"

153.335963

50

PROPANE

40,000

40.9

3"

20"

59V2"

* Limited usage ofT' vent pipe - see pages 16 and 19.

6

Page 6
Image 6
Kenmore 153.335943 Product, Specifications, Customer Responsibilities, Recovery, In Inches, Model Number, Heightto, 59V2