INSTALLATION REQUIREMENTS INSTALLATION HARDWARE
Your air conditioner will install into standard double hung windows with actual clear opening widths of 22 to 36
inches (559mm to 914mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (331mm). Side louvers and the rear of the air conditioner must have clear
air space to allow enough airflow through the condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
22"to36"qI
| 1113"m'ninnersilll. I _ | Window | |
f" | Offset | ||
|
| Sash | |
| _,_ |
| si, |
| _,1 | t ,_'_ | Exterior |
| Interiorw'_l\'4 | l," | FIG. 1 |
| ÷ |
|
ELECTRICAL SERVICE
Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on right side of cabinet).
All models are equipped with a
to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.
ITEM | NAME OF PARTS | Q"FY |
A | SHORT SCREW | 11 |
B | WOOD SCREW | 5 |
C | L BRACKET | 3 |
D | FOAM STRIP | 1 |
E | FOAM SEAL | 1 |
F | SIDE CURTAIN | 2 |
G | DRAIN PIPE | 1 |
H | SUPPORT BRACKET | 1 |
_!_ | [_:TIJ i [*] _1 |
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
•Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are needed to move and install the unit.
To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
•Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.
•Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.
•Make sure air conditioner does not fall during installation.
REQUIRED TOOLS:
•Tight Fitting gloves
•Standard screwdriver
•Phillips screwdriver
•Pliers
•Sharp knife
•
•
•Tape measure
•Electric drill
•