OTHERTHINGSTOKNOW
SECTION 4
21
4B.DIMENSIONS/SPECIFICATIONSFIG.16 BYPASSVALVES

Bypassvalve(s) should always remain in soft

water service position. Position in bypass

only if needed for softener repairs.

A
B
C
DE
F
INCHESCM
ASaltTankHeight40-1/4 102.2
BResin TankDiameter(nominal)8 20.3
CResin TankHeight(nominal)40 101.6
DInlet-OutletHeight41-1/2 105.4
EOverall height46 116.8
F1Length19-1/2 49.5
F2Width16-1/2 41.9
Distancebetweeninlet-outlet
centerlines3-3/8 8.6
MODELNO.625.348321

NOTE:

Pleaseseetheratingdecalforwatersofteneroperatingcapacity,saltusageandserviceflowrate/pressureloss
performancespecifications.PerformancespecificationsarevalidatedbytheWaterQualityAssociation(WQA).
Theratingdecal islocatedontherim,underthesaltholecover(see page32).
WATERSUPPLYTOWATERSOFTENER
MINIMUMWATERSYSTEMFLOW(gpm)3
MINIMUM-MAXIMUMWATERPRESSURE(psi)20-120
MAXIMUMWATERTEMPERATURE(5F)120
MAXIMUMWATERHARDNESS(gpg)50
MAXMUMCLEARWATERIRON(ppm)2
SALTFORWATERSOFTENER
TYPEOFSALTNEEDEDNugget/Pellet
ALTERNATETYPEOFSALTPure,evaporated,compacted
watersoftenersalt
STORAGECAPACITY(pounds)200
OTHERS
TYPEOFIONEXCHANGEMATERIAL(resin)HighCapacity
AMOUNTOFRESIN(cu.ft.).52
REGENERATION(RECHARGE)CYCLETIME(min.)
FILL(factorysetting-timeisadjustable)8
BRINING/BRINERINSE 80
BACKWASH12
FASTRINSE 4
TOTALREGENERATIONTIME(factorysetting)118
gpm=gallonsperminutepsi=poundspersquareinch
gpg=grainspergallon ppm=partspermillion