WATERSOFTENERSTART-UP
SECTION 1
5
1B.CHECK LISTOFALL STEP-BY-STEP GUIDES TOINSTALL
Refer to the Installation Manual, part no.
7159931, for step-by-step guides.
Tobe sure you have done all the steps to install
the softener, readthe following list. Page num -
bers referred to arein the Installation Manual.
nIs the house water flow going INTOthe soft -
ener valve INLET? Trace piping to be sure.
See pages 10 and 11.
nIsthe plumbing bypass valve (or 3 valves) set
forSERVICE? Bypass valve(s) should always
remain in soft water service position. Posi-
tion in bypassonly if needed for softener
repairs. See page 18.
nIs the valve drain hose connected the right
way,and without sharp bends or kinks that
couldstop or reduce water flow? See page 16.
nIs the softener power cable connected to the
transformer,and is the transformer plugged
into an inside, 120V-60Hz electrical outlet?
See page 20.
nBe sure to restart the water heater.See page
20.
Note,forinstallationsintheStateofMassachusetts:
PlumbingcodesofMassachusetts shall be adheredto.
Consult withyourlicensed plumber.
brass 3--valve
plastic
Bypass
Valves
Water
Heater