Kenmore 625.38376 Pressure Drop PSI vs. Flow Rate GPM, Questions? Call The Kenmore Water Line

Models: 625.38376

1 48
Download 48 pages 54.31 Kb
Page 34
Image 34
Pressure Drop (PSI) vs. Flow Rate (GPM)

Pressure Drop (PSI) vs. Flow Rate (GPM)

40

35

30

25

g

t_ 20

.=

 

15

370

Series

I/1

9.0gpm

@ 12 psi

 

 

 

lO

5

0

E

i

i

i

i

J

L

E

01 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Flow Rate (GPM)

FIG. 58

Intermittent flow rate does not represent the maximum service flow rate used for determining the soften- ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.

OTHER

SPECIFICATIONS

 

 

MODEL 38376

MODEL

39376

Type of ion exchange material (resin)

high capacity

high capacity

Amount

of

resin

(cu. ft.)

 

 

1.05

1.05

Rated Softening

Capacity

(Grains

@ Pounds Salt Dose)

11,200

@ 2.2

11,200 @ 2.2

 

 

 

 

 

 

30,000

@ 8.3

30,000

@ 8.3

 

 

 

 

 

 

37,900

@ 14.3

37,900

@ 14.3

Efficiency

Rating

(Grains

/ Pound

of Salt @ Minimum Salt Dose)

5070

@ 2.2

5070

@ 2.2

Rated Service Flow Rate (gpm)

 

9.0

9.0

Pressure

Drop at Rated Service Flow Rate (psi)

12

12

Intermittent

Flow

@ 15 psi (gpm)

 

10.4

10.4

Max. Drain Flow Rate (gpm)

 

2.0

2.0

These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat- ed by test data.

The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency rated according to NSF /ANSI Standard 44.

Questions? Call The Kenmore Water Line 1-800-426-9345

34

Page 34
Image 34
Kenmore 625.38376 owner manual Pressure Drop PSI vs. Flow Rate GPM, Questions? Call The Kenmore Water Line