A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Always make
the initial checks, and the manual initiated diag- nostics.
Notes:
The faceplate display must show a steady time (not
flashing). If an error code shows, first press the SE-
LECT button to enter the diagnostic display.
ffi Press the
3 seconds. RECHARGE begins to flash as the
softener enters the fill cycle of regeneration. Re-
move the brinewell cover and, using a flashlight,
observe fill water entering the tank.
a. If water does not enter the tank, look for an ob- structed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt | storage tank) 0.3 | (1.1 | liters) | ||
BRINING | '_ | .13 | (.5 liters) | ||
BACKWASH | to | 1.8 | (6.8 | liters) | |
drain) | .1 (.38 liters) | ||||
BRINE | RINSE | I (flow | |||
FAST | RINSE |
| 1.8 | (6.8 | liters) |
ffi Again press
ener into backwash. Look for a fast flow of water from the drain hose.
a. An obstructed flow indicates a plugged top dis-
tributor, backwash flow plug, or drain hose.
ffi Press
fast rinse, Again look for a fast drain flow. Allow the softener to rinse for a few minutes to flush out
any brine that may remain in the resin tank from the brining cycle test.
To return the softener to service, press ON/OFF- HOLD.
BRINE VALVE , ' FLOAT SETTING
_./float stop
ffi After observing fill, press the
into the brinewell and observing a noticeable drop in the liquid level.
Note:
Be sure a salt bridge is not preventing water with salt contact.
FREEBOARD MEASUREMENT
(Distance from top of resin tank, to top of resin bed.
a. If the softener does not draw brine...
...nozzle and/or venturi dirty or defective.
...nozzle and venturi not seated properly on gasket.
...restricted drain (check drain fitting and hose).
... defective nozzle and venturi seal.
...other inner valve defect rotor seal, rotor & disc, wave washer, etc.).
Note:
If water system pressure is low, an elevated drain
hose may cause back pressure, stopping brine draw.
resin tank
FREEBOARD