Toshiba B-SX8T SERIES Threshold Setting Cont, „ When using the Black Mark Sensor, E2-80

Models: EO1-33057D B-SX8T SERIES EO1-33057

1 139
Download 139 pages 1006 b
Page 94
Image 94
„When using the Black Mark Sensor
<5>SENSOR ADJ. [PEFLECT] 3.5V

2.PRINTER SETUP

ENGLISH VERSION EO1-33057

2.12 Threshold Setting

2.12Threshold Setting (Cont.)

„When using the Black Mark Sensor

(1)While “<5>SENSOR ADJ.” is displayed, press the [PAUSE] key until the message appears.

The displayed value is a real-time voltage being detected by the Black Mark Sensor.

Voltage at a black mark

Midpoint (Threshold voltage)

Voltage at a print area

<5>SENSOR ADJ. [REFLECT] 3.5V

<5>SENSOR ADJ. [REFLECT] 4.8V*

<5>SENSOR ADJ. [TRANS.] 2.4V

Voltage at a label gap

Midpoint (Threshold voltage)

Voltage at a print area

<5>SENSOR ADJ. [TRANS.] 2.4V

<5>SENSOR ADJ. [TRANS.] 2.4V*

<5>SENSOR ADJ. [PE]R0.1V T4.8V

(2)Measure a voltage at a blank part of media and a black mark, respectively. At this time, write down the midpoint between both voltages. (This value is used later for a threshold setting.)

(Example)

 

Print area = 4.8V, Black mark = 2.4V

Midpoint = 3.6V

NOTES:

1.When measuring a voltage of a blank area, be careful not to align a pre-print with the sensor by mistake.

2.Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position cannot be detected. In that case, please consider changing the media type.

3.Make sure that the Top Cover is closed when measuring the voltages.

(3)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Black Mark Sensor.

(4)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.

(5)A real-time voltage being detected by the Feed Gap Sensor is displayed.

„When using the Feed Gap Sensor

(1)Measure a voltage at a blank part of label and a label gap, respectively. At this time, write down the midpoint of both voltages. (This value is used later for a threshold setting.)

(Example)

 

Print area = 2.4V, Gap = 4.0V

Midpoint = 3.2V

NOTES:

1.When measuring a voltage at a blank area, be careful not to align a pre-print with the sensor by mistake.

2.Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position cannot be detected. In that case, please consider changing the media type.

3.Make sure that the Top Cover is closed when measuring the voltages.

(2)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Feed Gap Sensor.

(3)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.

(4)The display changes as shown on the left.

E2-80