(8) LCD Language Selection

2. PRINTER SETUP

ENGLISH VERSION EO1-33057

2.8 Setting an Operating Environment

2.8.1Parameter Setting (Cont.)

(8) LCD Language Selection

This parameter is to choose a language in which the LCD message is displayed.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET LCD ENGLISH

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

ENGLISH

ITALIAN

JAPANESE

SPANISH

DUTCH

FRENCH

GERMAN

NOTES:

1.If the printer is not used for a few days, the top edge of the media may become curly, which may cause a paper jam. The Auto Forward Wait Function prevents this problem since the media feed amount is increased so that the media stops past the platen.

2.When the Stop Position Fine Adjustment Value is set in + direction, the media will stop past the media outlet.

When the value is set in – direction, the media will stop inside the media outlet.

3.This setting will be useful to fine adjust the cut position of labels.

After selecting a language, press the [PAUSE] key.

(9) Auto Forward Wait Selection

This parameter is to choose whether to activate the Auto Forward Wait function or not.

This function, used in the cut mode, automatically feeds the media forward for about 14 mm if there is more than 1-second idle time after printing, to prevent the top edge of the media from curling.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET FORWARD WAIT OFF

Use the [FEED] or [RESTART] key to select a desired option.

 

 

 

 

 

 

 

Activated

 

 

 

 

 

 

FORWARD WAIT ON

 

[RESTART]

 

 

 

 

 

 

 

 

 

 

 

[FEED]

 

 

FORWARD WAIT OFF

Not activated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After selecting an auto forward wait, press the [PAUSE] key.