SECTION 5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC | ELECTRONIC | DIAGNOSTICS | ||||||
The | faceplate | timer | (PWA) | com- |
|
| ||
puter | has | a | func- |
|
| |||
tion | for | the | electrical | system, | ex- | EFr | 0 | |
cept for input power and water |
|
| ||||||
meter. | The | computer | monitors | electronic compo- | ||||
nents | and | circuits for | correct | operation. Ifa | malfunc- |
tion occurs, an error code appears in the faceplate display.
The chart below shows the error codes that could appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but-
ton. SELECT remains operational so the service per-
son can make the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS (below) to further isolate the defect, and check the water meter.
POSSIBLE DEFECT
CODE
Err1, Err3,
Err4
Err5
MOST LIKELY | ]D,. LESS LIKELY |
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing hiqh torque
faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer from outlet 2. Correct
defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS
To enter diagnostics, press the SELECT button until 000 - - shows in the display.
] | |
!,.JU U - | - |
A. The first 3 digits indicate water meter operation as follows:
000 (steady) = Soft water not in use, and no
flow through the meter.
--OPEN A NEARBY SOFT WATER FAUCET--
000 to 199 (continual) = Repeats display for each
gallon of water passing through the meter.
If you don't get a reading in the display with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing and check the turbine for binding.
POSITION
SWITCH
SENSOR
RBINE
lINE
SUPPORT AND
SHAFT
VALVE
OU
B° The letter (P) and dashes indicate POSITION
switch operation. If the letter appears, the switch is closed. If the dashes show, the switch is open.
Use the RECHARGE button to manually ad- vance the valve into each cycle and check correct switch operation.
5-2
Problems, Questions? Call