Kenmore 625.38818, 625.38817 Service Tech. Information, floa, A. Troubleshooting, Section

Models: 625.38817 625.38818

1 32
Download 32 pages 14.88 Kb
Page 23
Image 23
CYCLE FLOW RATES (GALLONS PER MIN.)

SECTION 5

SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve

motor, brine tank fill, brine draw, regeneration flow

rates, and other controller functions. Always make

the initial checks, and the manual initiated diag- nostics.

Notes:

The faceplate display must show a steady time (not flashing). If an error code shows, first press the SE-

LECT button to enter the diagnostic display.

Press the RECHARGE button and hold in for 3

seconds. RECHARGENOWbegins to flashinthe display as the softener enters the fill cycle of re-

generation. Remove the brinewell cover and, us-

ing a flashlight, observe fill water entering the tank.

a. If water does not enter the tank, look for an ob- structed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FILL (flow to salt storage

tank)

0.3

(1.1

liters)

BRINING

_

 

.15

(.57

liters)

 

 

to

 

 

 

MAX. BACKWASH

I

drain)

2.0

.6

liters)

BRINE RINSE

(flow

.1

(7.38

MAX. FAST RINSE

 

 

2.0

(7.6

liters)

After observing fill, press the RECHARGE but-

ton to move the softener into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight

into the brinewell and observing a noticeable drop in the liquid level.

Note:

Be sure a salt bridge is not preventing water with salt contact.

a. If the softener does not draw brine...

...nozzle and/or venturi dirty or defective.

...nozzle and venturi not seated properly on gasket.

...restricted drain (check drain fitting and hose).

...defective nozzle and venturi seal.

...other inner valve defect (rotor seal, rotor & disc, wave washer, etc.).

Note:

If water system pressure is low, an elevated drain hose may cause back pressure, stopping brine draw.

Again press RECHARGE to move the softener

into backwash. Look for a fast flow of water from

the drain hose.

a. An obstructed flow indicates a plugged top dis-

tributor, backwash flow plug, or drain hose.

Press RECHARGE to move the softener into fast

rinse. Again look for a fast drain flow. Allow the

softener to rinse for a few minutes to flush out

any brine that may remain in the resin tank from

the brining cycle test.

To return the softener to service, press RE-

CHARGE.

17BRINE VALVE , ' FLOAT SETTING

/_ float stop

floa,

FREEBOARD MEASUREMENT

Distance from top of resin tank, to top of resin bed.)

t

resin tank

FREEBOARD

7"-11"

1

5-4

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Page 23
Image 23
Kenmore 625.38818 Service Tech. Information, floa, A. Troubleshooting, Section, Cycle Flow Rates Gallons Per Min