SECTION 5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the initial checks, and the manual initiated diag- nostics.
Notes:
The faceplate display must show a steady time (not flashing). If an error code shows, first press the SE-
LECT button to enter the diagnostic display.
Press the RECHARGE button and hold in for 3
seconds. RECHARGENOWbegins to flashinthe display as the softener enters the fill cycle of re-
generation. Remove the brinewell cover and, us-
ing a flashlight, observe fill water entering the tank.
a. If water does not enter the tank, look for an ob- structed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)FILL (flow to salt storage | tank) | 0.3 | (1.1 | liters) | |
BRINING | _ |
| .15 | (.57 | liters) |
|
| to |
|
|
|
MAX. BACKWASH | I | drain) | 2.0 | .6 | liters) |
BRINE RINSE | (flow | .1 | (7.38 | ||
MAX. FAST RINSE |
|
| 2.0 | (7.6 | liters) |
After observing fill, press the RECHARGE but-
ton to move the softener into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable drop in the liquid level.
Note:
Be sure a salt bridge is not preventing water with salt contact.
a. If the softener does not draw brine...
...nozzle and/or venturi dirty or defective.
...nozzle and venturi not seated properly on gasket.
...restricted drain (check drain fitting and hose).
...defective nozzle and venturi seal.
...other inner valve defect (rotor seal, rotor & disc, wave washer, etc.).
Note:
If water system pressure is low, an elevated drain hose may cause back pressure, stopping brine draw.
Again press RECHARGE to move the softener
into backwash. Look for a fast flow of water from
the drain hose.
a. An obstructed flow indicates a plugged top dis-
tributor, backwash flow plug, or drain hose.
Press RECHARGE to move the softener into fast
rinse. Again look for a fast drain flow. Allow the
softener to rinse for a few minutes to flush out
any brine that may remain in the resin tank from
the brining cycle test.
To return the softener to service, press RE-
CHARGE.
17BRINE VALVE , ' FLOAT SETTING
/_ float stop
floa,
FREEBOARD MEASUREMENT
Distance from top of resin tank, to top of resin bed.)
t
resin tank
FREEBOARD
1