Water circulation

The circulation pump pumps water from the sump through a triple filter system to the heater. When water enters the heater, a flow switch determines water is present and allows the heater to be activated. As water flows, it’s heated until it reaches the pre-set temperature determined by the cycle. Once it leaves the heater, it flows through the sump into the upper and lower spray arms.

Aqua

NTC Hi-limit

sensor

Heating element

To upper

spray arm

To lower

spray arm

Backflow

valveCirculation pump motor

Drain pump

 

 

 

 

 

 

 

cover

 

 

 

 

 

 

 

 

 

 

 

Sump

 

 

 

 

 

 

 

Drain pump

Seal

 

 

 

 

 

Impeller

 

 

 

 

 

 

 

 

The aqua sensor, drain pump, NTC, Hi-limit and backflow valve are near the heater under the sump. The aqua sensor senses water cleanliness – dishwashers add or subtract rinses as needed. The NTC senses water temperature. The Hi-limit shuts off the heater if the water gets too hot. The backflow valve prevents waste water from entering the dishwasher.