To remove complete pump

Repair

To remove complete pump

Tools needed: flat blade screwdriver.

1.Use a small flat blade screwdriver to carefully push in the pump housing latch and rotate the pump clockwise (cw) to remove the pump (1).

2.Disconnect wire harness from pump motor after carefully noting connections (2).

CAUTION: Don’t grab motor next to the capacitor to avoid jamming your hand on the capacitor.

TIP: Pump motors can have a plastic (newer) or metal (older) housing. Pumps with plastic motor housings cannot be removed by blocking up the tank unless the capacitor is removed first (since the capacitor hits the tank when the pump is rotated).

VD. Controls

Fascia panel mounted controls

Controls are easily removed from fascia panels by bending console tabs.

Tools needed: T-20 Torx & flat blade screwdrivers.

1.Remove fascia panel by removing T-20 Torx inner door screws.

2.Disconnect wire harnesses from module after noting connector locations.

3.Pry out metal console tabs holding module to console.

4.Carefully pry back plastic tabs, then slide module from console.

702_58300000149896_ara_en_b

Page 32
Image 32