Instatl the shutoff valve on the nearest frequently used drinking water line.

1. SHUT OFF THE MAIN WATER SUPPLY

Turn on the nearest faucet to relieve the pressure on the line.

2.CHOOSE THE VALVE LOCATION

Choose a location for the valve that is

easily accessible,

it is best

to

connect

 

into the side of a vertical water pipe.

 

When it is necessary to connect into

m

a horizontai

water

pipe, make

the

connection

to the top or side, rather

 

than at the

bottom, to

avoid

drawing

 

off any sediment

from

the

water pipe.

 

3. DRILL THE HOLE FOR THE VALVE

Drill a I/4 in. hole in the water pipe using a sharp bit. Remove any burrs resulting from

drilling the hole in the pipe. Be careful not to allow water to drain into the drill. Failure to drill a 1/4 in. hole may result

in reduced ice production or smaller cubes.

NOTE: The hookup line cannot be white, plastic tubing. Licensed plumbers must use only copper tubing NDA tubing :#49595 or 49599 or Cross Link Polyethylene (PEX) tubing.

4.FASTEN THE SHUTOFF VALVE

Fasten the shutoff valve to the cold water pipe with the pipe clamp.

Pipe Clamp-

Saddle-Ty_

Vertical

Cold

Shutoff Valve

Water

Pipe

NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegat and use is not permitted in Massachusetts. Consult with your licensed plumber.

5. TIGHTEN THE PiPE CLAMP

Tighten the clamp screws until the sealing washer begins to swell.

NOTE: Do not overfighten damp or you may crush the tubing.

Washer

,--------inlet End

Pipe Clamp

Clamp Screw_

o ROUTE THE TUBING

Route the tubing between the cold water line and the refrigerator.

Route the tubing through a hole drilled in the wall or floor (behind the refrigerator or adjacent base cabinet) as close to the wall as possible.

NOTE: Be sure there is sufficient extra tubing (about

8 feet coiled into 3 turns of about 10 in. diameter) to allow the refrigerator to move out from the wall after installation.

7.CONNECT THE TUBING TO THE VALVE

Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect it to the shutoff valve. Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely.

Saddle-Type

 

 

Shutoff

Valve

_

, b

 

X

 

Packing Nu_

 

ression Nut

 

 

 

Outlet

Valve--

 

Ferrule (sleeve)

NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are

illegal and their use is not permitted in Massachusetts. Consult with your licensed plumber.