Kenmore L53.335816 Customer Responsibilities, Product, Tank, Dimensions In Inches, Specifications

Models: 153.335862 153.335942 153.335916 153.335962 153.335845 L53.335816

1 40
Download 40 pages 985 b
Page 6
Image 6
Customer Responsibilities

Customer Responsibilities

Thank You for purchasing a Sears water heater. Properly instaRled and maintained, it should give you years of trouble free ser- vice. If you should decide that you want the new water heater profes- sionally installed by Sears call the local Sears Service Center or any

Sears store. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual

I.A.S. - International Approval Services, A Division of CSA A.N.S.I. - American National Standards Ins6tute

AWARNING

This gas-fired water heater is design certified by the International Approval Services, A Division of CSA under American National Standard/CSA Standard for Gas Water

Heaters ANS Z21.10.1 • CSA 4.1 (latest edition). The installation must conform with this manual, Local Codes

and with the latest edition of the National Fuel Gas Code,

ANSI Z223.1.

This publication is available from your local government or

_ublic library, gas company, or by writing NFPA, Batterymarch Park, Quincy, MA 02269.

Read the "Safety Precautions" section, pages 2 and 3 of this manual first and then the entire manualcarefully. If you don't

follow the safety rules, the water heater will not operate prop-

erl)_ It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, opera- tion, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential

to the proper operation of the water heater and your safety. ,_nce we cannot put everything on the first few pages, READ HE ENTIRE MANUAL BEFORE ATTEMPTING TO

INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this

manual; [_as company rules; and Local Codes, or in the absence otLocal Codes, with the latest edition of the National Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54. This publication is available from your local government or public library or gas company" or by writing NFPA, Batterymarch Park, Quincy, MA 02269.

lfafter reading this manual you have any questions or do not

understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe instal- lation are very iraportant in preventing death from possible carbon monoxide poisoning and fires.

Examine the location to ensure the water heater complies with the "Locating the New Water Heater" section in this manual.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Product

Specifications

 

 

 

 

 

 

TANK

TYPE

 

RECOVERY

MINIMUM

DIMENSIONS IN INCHES

 

 

RATE GALS.

 

HEIGHTTO

MODEL NUMBER

CAPACITY

OF

B.ZU.

PER HOUR

VENT

 

 

IN GALLONS

GAS

RATE

@ 90°F RISE

PIPE

DIAMETER JACKETTOP

153.335816

40

NATURAL

40,000

40.9

3"

18"

60"

153.335845

40

PROPANE

40,000

40.9

3"

18"

6O"

153.335862

40

PROPANE

40,000

40.9

3"

18"

6O"

153.335916

50

NATURAL

40,000

40.9

3"

20"

59½"

153.335942

50

PROPANE

40,000

40.9

3"

20"

59W'

153.335962

50

PROPANE

40,000

40.9

y'

20"

59_"

Page 6
Image 6
Kenmore L53.335816 Customer Responsibilities, Product, Tank, Dimensions In Inches, Diameter Jackettop, Specifications

FAQ

What are the installation requirements for Kenmore water heaters?

Properly install and maintain the water heater to ensure trouble-free service. For professional installation, contact Sears Service Center or any Sears store.

Where can I find safety precautions for the Kenmore water heater?

The safety precautions can be found in the 'Safety Precautions' section on pages 2 and 3 of the manual.

What are the venting requirements for the water heater?

Proper vent action and vent pipe installation are important to prevent carbon monoxide poisoning and fires. Refer to the manual for specific instructions.