Kenmore 153.335916, L53.335816, 153.335942, 153.335845, 153.335962 contd, Installation Instructions

Models: 153.335862 153.335942 153.335916 153.335962 153.335845 L53.335816

1 40
Download 40 pages 985 b
Page 17
Image 17
Installation Instructions

Installation Instructions

VENTING SYSTEM EXAMPLE INSTALLATIONS FOR ALL MODELS (cont'd)

, .

i - ,

2. Horizontal runs require

a mmtmum¼

rtse per foot.

13"MIN.

MIN. RISE7,"

I I" MIN.

PERFOOT

I

3.A vertical run can be no more than 20'.

4.The total vertical and horizontal run cannot exceed 35'.

MIN. RISE%"

(cont'd)

CEMENTING PVC, ABS OR CPVC PIPE AND FITTINGS

Read and observe all safety information printed on primer, cleaner, and cement containers.

DANGER

Primer, cleaner, and cements are extremely flammable. They are harmful or fatal if swallowed. The vapors are harmful. They may irritate eyes and skin and can be absorbed through the skin.

PRECAUTIONS

Always store primers, cleaner, and cements in cool, dry, well ventilated places. Do not store them near heat, sparks, or flames. Keep containers closed. Use them in well ventilated areas. Wear impervious clothing while handling. Do not smoke, eat, or drink while handling.

Wash thoroughly after handling and before eating. Wear

eye protection when handling. If swallowed, drink water, do not induce vomiting, and call a physician or poison control center immediately. If inhaled, get fresh air and seek medical attention if ill feelings persist. In case of eye and skin contact, immediately flush with plenty of water for 15 minutes and seek medical attention if irri- tation persists. KEEP OUT OR REACH OF CHILDREN.

All primers, cleaners, and cements must meet all local codes and

applicable standards of the American Society For Testing Materials Standards•

ONE ELBOW

MAX. 20'

PERFOOT

Before using primers, cleaners, and cements, stir or shake, mak-

in sure contents are liquid. Do not use if found to be lumpy or jelly-like.

TOTAL VERTICAL AND

HORIZONTAL RUNS

CANNOT EXCEED 35'

 

 

MIN. RISE ¼"

 

 

PER FOOT

MAX. 20'

ITOTAL VERTICAL

AND

 

 

HORIZONTAL

RUNS

HIN.

RISE ¼"

CANNOT EXCEED 35'

 

 

PER FOOT

I

1.Cut pipe ends squarely removing all burrs and dirt.

2.Dry fit pipe and fittings to be connected for proper fit.

3.Clean pipe and fitting with a primer/cleaner.

4.Apply a thin coat of cement to fitting, avoiding puddling inside.

5.Apply a liberal coat of cement to pipe leaving no voids.

6.QUICKLY assemble parts while cement is flui!! If you wait too long, re-coat pipes.

7.Push pire completely into socket of fitting, turning as it goes until _t oottoms.

8.Hold pipe and fitting together for 30 seconds. Then carefully clean off excess with a cloth. Allow connections a sufficient

time to cure before disturbing.

9.Remember that vent pipes must be adequately and securely supported.

APPROXIMATE SETTING TIME FOR 2V_,"TO 4" PIPE OINTS

 

MOVEMENT

COMPLETE

 

OF JOINT

SET

 

 

 

90°F to 150°F

_hr.

8

hrs.

50°F to 90°F

1 hr.

15

hrs.

0°F to 50°F

1_ hr.

18

hrs.

17

Page 17
Image 17
Kenmore 153.335916, L53.335816, 153.335942, 153.335845, 153.335962, 153.335862 owner manual contd, Installation Instructions

FAQ

What safety precautions should I take when handling primers, cleaners, and cements?

Always store primers, cleaners, and cements in cool, dry, well-ventilated places. Do not store them near heat, sparks, or flames. Keep containers closed. Use them in well-ventilated areas. Wear impervious clothing while handling. Do not smoke, eat, or drink while handling.

What is the approximate setting time for pipe joints?

The approximate setting time for pipe joints varies based on the temperature range. For example, at 90°F to 150°F, it takes 8 hours for the movement of the joint to set completely.

How do I properly cement PVC, ABS, or CPVC pipe and fittings?

Cut pipe ends squarely, removing all burrs and dirt. Dry fit pipe and fittings to be connected for proper fit. Clean pipe and fittings with a primer or cleaner. Apply a thin coat of cement to the fitting, avoiding puddling inside. Apply a liberal coat of cement to the pipe leaving no voids. Quickly assemble parts while the cement is fluid. Push pipe completely into the socket of the fitting, turning as it goes until it bottoms.