Kenmore L53.335816 Water Piping, Installation Instructions contd, Installation Completed Using

Models: 153.335862 153.335942 153.335916 153.335962 153.335845 L53.335816

1 40
Download 40 pages 985 b
Page 12
Image 12
Water Piping

Installation Instructions (cont'd)

Water Piping

AWARNING

HOTTER WATER CAN SCALD: Water heaters are intended to

Jmduce hot water. Water heated to a temperature which will satisfyclothes washing, dishwashing, and other sanitizing needs can scald and permanently injure you upon contact. Some pee- fie are more likely to be permanently injured by hot water than

2.Look at the top cover of the water heater. The cold water inlet is marked cold. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends oiCthe X" threaded nipple. Using flexi-

ble connectors, connect the cold water pipe to the coldwater inlet of the water heater.

others. These includethe elderly, children,the infirm, or physical- ly/mentally handicapped. If anyone usinghot water in your home fits into one of these groups or if there is a localcode or state law requiring a certain temperature water at the hot water tap, then _u must take special precautions.In addition to usingthe lowest

NOTE: This water heater is insulated to minimize heat loss from the tank. Further reduction in heat loss can be

accomplished by insulating the hot water lines from the water heater.

mssible temperature setting that satisfiesyour hot water needs, a means such as a mixing valve, shouldbe used at the hot water

taps used by these people or at the water heater. Mixing valves are availableat plumbing supplyor hardware stores. Follow man. ufacturers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the

"Temperature Regulation" section in this manual.

INSTALLATION COMPLETED USING

SEARS INSTALLATION KIT

COLD INLET

WATERLINE

THREADED TO SHUTOFF

SWEAT COUPLING VALVE

This water heater shall not be connected to any heating systems

or component(s) used with a non-potable water heating appli-

ance.

If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water meter with a check valve, etc.., in the cold water supply; means shall be provided to control thermal expansion. Contact the

local utility or local Sears Service Center on how to control this situation.

NOTE: To protect against untimely corrosion of hot and

cold water fittings, it is strongly recommended that dielec-

tric unions or couplings be installed on this water heater when connected to copper pipe.

The illustration shows the attachment of the water piping to the

water heater. The water heater is equipped with / inch water connections.

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connec-

tion. Do not solder the cold water supply line directly to the cold water inlet or it will harm the dip tube.

1.Look at the top cover of the water heater. "I'he hot water outlet is marked hot. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the X" th eaded npple. Us'ng flex'ble connectors, con

nect the hot water pipe to the hot water outlet on the water heater.

THREADED TO

SWEAT COUPLING

3!4" THREADED

 

 

NIPPLE

 

TEMPERATURE-

 

PRESSURERELIEF

 

VALVE

HOT OUTLET

 

TO HOUSE

 

NIPPLE

 

DISCHARGE PIPE (Do not cap or plug)

PROVIDE A 6" AIR

GAP BETVVEEN THE

END OF THE

DISCHARGE PIPE

AND DRAIN

12

Page 12
Image 12
Kenmore L53.335816 Water Piping, Installation Instructions contd, Installation Completed Using, Sears Installation Kit

FAQ

What precautions should be taken to prevent scalding from hot water?

Special precautions should be taken if anyone using hot water in your home fits into groups who are more likely to be permanently injured by hot water, or if there is a local code or state law requiring a certain temperature water at the hot water tap. A means such as a mixing valve should be used at the hot water taps used by these people or at the water heater.

Should dielectric unions or couplings be installed on the water heater when connected to copper pipe?

Yes, to protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that dielectric unions or couplings be installed on this water heater when connected to copper pipe.

What should be used to control thermal expansion if the water heater is installed in a closed water supply system?

Means shall be provided to control thermal expansion if a water heater is installed in a closed water supply system. Contact the local utility or local Sears Service Center on how to control this situation.