Installation Instructions (cont'd)
Water Piping
AWARNING
HOTTER WATER CAN SCALD: Water heaters are intended to
Jmduce hot water. Water heated to a temperature which will satisfyclothes washing, dishwashing, and other sanitizing needs can scald and permanently injure you upon contact. Some pee- fie are more likely to be permanently injured by hot water than
2.Look at the top cover of the water heater. The cold water inlet is marked cold. Put two or three turns of teflon tape around the threaded end of the
ble connectors, connect the cold water pipe to the coldwater inlet of the water heater.
others. These includethe elderly, children,the infirm, or physical- ly/mentally handicapped. If anyone usinghot water in your home fits into one of these groups or if there is a localcode or state law requiring a certain temperature water at the hot water tap, then _u must take special precautions.In addition to usingthe lowest
NOTE: This water heater is insulated to minimize heat loss from the tank. Further reduction in heat loss can be
accomplished by insulating the hot water lines from the water heater.
mssible temperature setting that satisfiesyour hot water needs, a means such as a mixing valve, shouldbe used at the hot water
taps used by these people or at the water heater. Mixing valves are availableat plumbing supplyor hardware stores. Follow man. ufacturers instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
"Temperature Regulation" section in this manual.
INSTALLATION COMPLETED USING
SEARS INSTALLATION KIT
COLD INLET
WATERLINE
THREADED TO SHUTOFF
SWEAT COUPLING VALVE
This water heater shall not be connected to any heating systems
or component(s) used with a
ance.
If a water heater is installed in a closed water supply system; such as one having a
local utility or local Sears Service Center on how to control this situation.
NOTE: To protect against untimely corrosion of hot and
cold water fittings, it is strongly recommended that dielec-
tric unions or couplings be installed on this water heater when connected to copper pipe.
The illustration shows the attachment of the water piping to the
water heater. The water heater is equipped with / inch water connections.
NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connec-
tion. Do not solder the cold water supply line directly to the cold water inlet or it will harm the dip tube.
1.Look at the top cover of the water heater. "I'he hot water outlet is marked hot. Put two or three turns of teflon tape around the threaded end of the
nect the hot water pipe to the hot water outlet on the water heater.
THREADED TO
SWEAT COUPLING | 3!4" THREADED |
| |
| NIPPLE |
| TEMPERATURE- |
| PRESSURERELIEF |
| VALVE |
HOT OUTLET |
|
TO HOUSE |
|
NIPPLE |
|
DISCHARGE PIPE (Do not cap or plug)
PROVIDE A 6" AIR
GAP BETVVEEN THE
END OF THE
DISCHARGE PIPE
AND DRAIN
12