Kenmore 153.335916 Chock 9 orl 0,120volts, Troubleshooting Guide contd, jIs indicator light on?

Models: 153.335862 153.335942 153.335916 153.335962 153.335845 L53.335816

1 40
Download 40 pages 985 b
Page 35
Image 35
volts.

Troubleshooting Guide (cont'd)

continued from facing page

1

Check #5 to ground for 110/120 __

No -fCheck#8togroundfor110/120volts.]-.,_--No

volts.

 

 

 

I

 

 

Yes

 

I Replace

indicator

light.

Yes

 

 

 

1

Secure

air pressure

line.

 

[Chock 9 orl 0,120volts].

-j Is indicator light on?

[

I

Yes

Is ¼" air pressure line secured to air

pressure switch with opposite end I secured to pressure tap on blower

housing? See 6 and 7.

I

 

 

 

Yes

No

Yes

 

Is there venting restriction or low

_-

No "-t voltage (110V rain. req.)

 

Replace air pressure switch.

Check venting manual reset switch.

I

Yes

l Remove restriction or correct voltage.

I Replace thermostat.

_,,_- No "t ls main burner on?

 

Yes

ALL SYSTEMS OPERATIONAL

35

Page 35
Image 35
Kenmore 153.335916, L53.335816, 153.335942 Chock 9 orl 0,120volts, Troubleshooting Guide contd, jIs indicator light on?

FAQ

How do I check for 110/120 volts?

Check #5 to ground for 110/120 volts. If not, check #8 to ground for 110/120 volts.

Is the indicator light on?

Yes - ensure air pressure line is secured to the air pressure switch and pressure tap. No - check for venting restriction or low voltage.

How do I make sure all systems are operational?

Check venting, manual reset switch, thermostat, and main burner for proper functioning.