Installation Instructions (cont'd)

Installation Instructions (cont'd)

IIWARNING

A gaswater heater cannotoperate properlywithout the cor- rect amount of air for combustion.Do not install in a con-

fined area such a closet, unlessyou provide air as shownin the "Locating The New Water Heater" section. Never obstruct the flow of ventilationair. If you haveany doubtsor questionsat all, callyour gascompany.Failureto providethe proper amountof combustionair canresultin a fire or explo- sionand can causeDEATH, SERIOUS BODILY INJUR_,OR PROPERTYDAMAGE.

li WARNING

If this water heater willbe usedin beautyshops,barber shops, cleaning establishments,or self-servicelaundrieswith dry cleaningequipment, it is imperativethat the water heater or water heaters be installedsothat combustionand ventilation

air be taken from outsidetheseareas. Referto the "Locating The New Water Heater" sectionof this manualand also the

latest editionof the NationalFuelGasCode,ANSI Z223.1,also referred to as NFPA 54 for specificsprovidedconcerningair required.

Figure 2 ]

from any overhang

of Flue

Combustion Air and Ventilation

When determining the installation location for apower vent water heater, snow accumulation and drifting shouldbe consid- ered in areas where applicable.

VENTING CLEARANCES

0" clearance for 3" PVC, ABSor CPVC Schedule 40 vent piping

 

from combustible surfaces.

12" minimum from the ground, 18" ceilingoverhangs.Figure2.

• The Power Vent outlet terminal shall terminate at least 3 feet above

 

any forcedair inlet locatedwithin 10 feet. Figure3a.

• The PowerVent outlet terminal shall terminate at least4 feet below,

 

4 feet horizontallyfrom or 1 foot aboveany door, window or gravity

 

air inlet into the building. Figure3a.

18" minimum in all directions from any obstruction that may

 

interfere.Figure3b.

18" minimum from other gravityor natural appliance outlet vents

 

when directlyaboveor 135° to either sideof center line. Figure3c.

36" minimum from any outlet vents when directlybelow or 45° to

 

either sideof center line. Figure3c.

36" minimum in all directionsfrom any other forced air appliance

 

outlet vent. Figure3c.

The location selection must provide clearances for servicing and

 

proper operation of the water heater. Figure4.

Vent termination must not be within 4 feet of any itemssuch as gas

 

meters,gas valvesor other gas regulatingequipment.

The venting system must be installed in a manner which allows

 

inspection of the installationof the venting pipes and joints as well

TERMINAL 12" min.

INLET

Figure 3a]

S

VENT TERMINAL

 

 

 

IB" TO WALL OR OTHER

L_

I E" MIN,

OBSTRUCTIONS THAT

MAY INTERFERE WITH

 

 

 

 

VENTING.

 

rF

VENT TERMINAL

[F,gu3b].

 

 

CORNER OF BUILDING

 

 

 

 

POWER VENT

TERHINAL

_

J_

_\

*THIS DIMENSION

IS

INCREASED TO 36" WHEN

 

 

_

 

_

__

_-- -

_ _"

_THE

VENT OUTLET

IS FOR A

 

_

_

 

_j_

FORCED VENT APPLIANCE

 

 

_B"*/'

 

 

 

-

 

"- _

' _

_-DIRECTVENTOR

 

 

 

_

_

 

GRAVITY VENTED

 

 

 

36,_ _--'-

\ _

APPLIANCE

 

 

 

 

45°

 

 

 

as periodic inspection after installation as required by ANSI

Standards.

iI WARNING

Ventterminationmust not bewithin4 feet of anyitemssuchas gasmeters,gasvalvesor other gasregulating equipment.

[Figure3cI

Must maintain

adequate service and maintenance

ibility.

ANY OTHER OUTLET VENT

iIWARNING

Failureto haverequired clearancesbetweenwater heater and combust b e mater al w resut n a fire hazard.

 

Range of degrees

[ Figure 4 ]

available for vent

 

pipe installation.

10

Page 10
Image 10
Kenmore 153.335862 Installation Instructions contd, cI, Combustion Air and Ventilation, iIWARNING, F,gu3b, Iiwarning

FAQ

What are the installation requirements for Kenmore Water Heater models?

The installation instructions vary based on the model. Please refer to the specific manual for your model for detailed requirements.

Can the water heater be installed in a confined area?

A gas water heater should not be installed in a confined area unless proper ventilation and combustion air are provided.

What are the minimum clearances required for vent piping?

The vent piping should have 0" clearance from combustible surfaces, 12" minimum from the ground, and 18" from ceiling overhangs.