Installation Instructions (cont'd)
IIWARNING
A gaswater heater cannotoperate properlywithout the cor- rect amount of air for combustion.Do not install in a con-
fined area such a closet, unlessyou provide air as shownin the "Locating The New Water Heater" section. Never obstruct the flow of ventilationair. If you haveany doubtsor questionsat all, callyour gascompany.Failureto providethe proper amountof combustionair canresultin a fire or explo- sionand can causeDEATH, SERIOUS BODILY INJUR_,OR PROPERTYDAMAGE.
li WARNING
If this water heater willbe usedin beautyshops,barber shops, cleaning establishments,or
air be taken from outsidetheseareas. Referto the "Locating The New Water Heater" sectionof this manualand also the
latest editionof the NationalFuelGasCode,ANSI Z223.1,also referred to as NFPA 54 for specificsprovidedconcerningair required.
Figure 2 ]
from any overhang
of Flue
Combustion Air and Ventilation
When determining the installation location for apower vent water heater, snow accumulation and drifting shouldbe consid- ered in areas where applicable.
VENTING CLEARANCES
• | 0" clearance for 3" PVC, ABSor CPVC Schedule 40 vent piping |
| from combustible surfaces. |
• | 12" minimum from the ground, 18" ceilingoverhangs.Figure2. |
• The Power Vent outlet terminal shall terminate at least 3 feet above | |
| any forcedair inlet locatedwithin 10 feet. Figure3a. |
• The PowerVent outlet terminal shall terminate at least4 feet below, | |
| 4 feet horizontallyfrom or 1 foot aboveany door, window or gravity |
| air inlet into the building. Figure3a. |
• | 18" minimum in all directions from any obstruction that may |
| interfere.Figure3b. |
• | 18" minimum from other gravityor natural appliance outlet vents |
| when directlyaboveor 135° to either sideof center line. Figure3c. |
• | 36" minimum from any outlet vents when directlybelow or 45° to |
| either sideof center line. Figure3c. |
• | 36" minimum in all directionsfrom any other forced air appliance |
| outlet vent. Figure3c. |
• | The location selection must provide clearances for servicing and |
| proper operation of the water heater. Figure4. |
• | Vent termination must not be within 4 feet of any itemssuch as gas |
| meters,gas valvesor other gas regulatingequipment. |
• | The venting system must be installed in a manner which allows |
| inspection of the installationof the venting pipes and joints as well |
TERMINAL 12" min.
INLET
Figure 3a]
S | VENT TERMINAL |
| |
|
| IB" TO WALL OR OTHER | |
L_ | I E" MIN, | OBSTRUCTIONS THAT | |
MAY INTERFERE WITH | |||
|
| ||
|
| VENTING. | |
| rF | VENT TERMINAL |
[F,gu3b]. |
|
| CORNER OF BUILDING | ||||
|
|
|
| ||||
POWER VENT | TERHINAL | _ | J_ | _\ | *THIS DIMENSION | IS | |
INCREASED TO 36" WHEN | |||||||
|
| _ |
| _ | |||
__ | _ _" | _THE | VENT OUTLET | IS FOR A | |||
| _ | _ |
| _j_ | FORCED VENT APPLIANCE | ||
|
| _B"*/' |
|
|
| ||
- |
| "- _ | ' _ |
| |||
|
| _ | _ |
| GRAVITY VENTED |
| |
|
| 36,_ | \ _ | APPLIANCE |
| ||
|
|
| 45° |
|
|
|
as periodic inspection after installation as required by ANSI |
Standards. |
iI WARNING
Ventterminationmust not bewithin4 feet of anyitemssuchas gasmeters,gasvalvesor other gasregulating equipment.
[Figure3cI
Must maintain
adequate service and maintenance
ibility.
ANY OTHER OUTLET VENT
iIWARNING
Failureto haverequired clearancesbetweenwater heater and combust b e mater al w resut n a fire hazard.
| Range of degrees |
[ Figure 4 ] | available for vent |
| pipe installation. |
10