Features

After seven (7) years of cumulative power up, this unit will “chirp” every 30 seconds. This is an "operational end of life" feature which will indicate that it is time to replace the alarm.

Loud 85 decibel alarm

Oversized test button for easy activation

Test button performs the following functions:

Tests the units electronics and verifies proper unit operation

Resets the unit during CO alarm

Peak Level Memory (see page 16)

Activates Hush® Feature (see page 17)

Mounting bracket designed for easy orientation of unit

Green and red LED lights that indicate normal operation and alarm status

Green Light: The green LED light flashes every 30 seconds to indicate the unit is operating properly and once every 2 seconds to indicate the unit is in HUSH® mode. The green light also flashes before a CO reading is taken and when any button is pressed.

Red Light: When a dangerous level of smoke or carbon monoxide is detected the red LED light will flash and the corresponding alarm pattern (depending on the source) will sound. If the unit malfunctions, the red LED light will flash and the unit will chirp every 30 seconds indicating a system problem.

Powered by three (3) AA batteries

Battery lockout system that prohibits installation without using three batteries

Tamper Resist Feature that deters children and others from removing the alarm

5