16 | Appendix B Cabling Guidelines |
Appendix B Cabling Guidelines
Cable Types
When connecting network cables, the following table shows appropriate networking guidelines associated with each cable type.
| Ethernet Standard: |
|
| 10BASE5 |
|
| 10BASE2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cable Type: |
|
|
|
|
|
| UTP CAT |
| ||
|
|
|
|
|
|
|
|
|
| 3, 4 or 5 |
|
| Max. Segment |
|
| 500M |
|
| 185M |
|
| 100M |
|
| Length: |
|
| (1640ft) |
|
| (600ft) |
|
| (328ft) |
|
| Max. Number of |
| 100 |
| 30 |
| 1024 |
| |||
| Nodes per Segment: |
|
|
|
| ||||||
| Connector: |
|
|
|
| BNC |
|
|
| ||
| Network Topology: |
|
| Linear Bus |
|
| Linear Bus |
|
| Star |
|
Table
UTP Cable Wiring
Pin Number | Pin Number | ||
1 | (TRX +) | 1 | (TRX +) |
|
|
|
|
2 | (TRX | 2 | (TRX |
|
|
|
|
3 | (RCV +) | 3 | (RCV +) |
|
|
|
|
6 | (RCV | 6 | (RCV |
|
| ||
4, 5, 7, 8 | Not Used | ||
|
|
|
|
Table
Crossover”
Cable Wiring
Pin Number | Pin Number | ||
1 | (TRX +) | 3 | (RCV +) |
|
|
|
|
2 | (TRX | 6 | (RCV |
|
|
|
|
3 | (RCV +) | 1 | (TRX +) |
|
|
|
|
6 | (RCV | 2 | (TRX |
|
| ||
4, 5, 7, 8 | Not Used | ||
|
|
|
|
Table