16

Appendix B Cabling Guidelines

Appendix B Cabling Guidelines

Cable Types

When connecting network cables, the following table shows appropriate networking guidelines associated with each cable type.

 

Ethernet Standard:

 

 

10BASE5

 

 

10BASE2

 

 

10BASE-T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable Type:

 

 

RG-11

 

 

RG-58/U

 

 

UTP CAT

 

 

 

 

 

 

 

 

 

 

 

3, 4 or 5

 

 

Max. Segment

 

 

500M

 

 

185M

 

 

100M

 

 

Length:

 

 

(1640ft)

 

 

(600ft)

 

 

(328ft)

 

 

Max. Number of

 

100

 

30

 

1024

 

 

Nodes per Segment:

 

 

 

 

 

Connector:

 

 

15-pin D-Sub

 

 

BNC

 

 

RJ-45

 

 

Network Topology:

 

 

Linear Bus

 

 

Linear Bus

 

 

Star

 

Table B-1 Network Cable Guidelines

UTP Cable Wiring

10BASE-T unshielded twisted-pair cables can be wired as "Straight-Thru" or, in some cases, "Crossover" depending on the application. For workstations connected to a hub, use "Straight-Thru' wiring illustrated below in Table B-2. In some instances (e.g. cascading from one hub to another), you may use "Crossover" wiring illustrated below in Table B-3.

"Straight-Thru" Cable Wiring

Pin Number

Pin Number

1

(TRX +)

1

(TRX +)

 

 

 

 

2

(TRX -)

2

(TRX -)

 

 

 

 

3

(RCV +)

3

(RCV +)

 

 

 

 

6

(RCV -)

6

(RCV -)

 

 

4, 5, 7, 8

Not Used

 

 

 

 

Table B-2. Straight-Thru Wiring

Crossover”

Cable Wiring

Pin Number

Pin Number

1

(TRX +)

3

(RCV +)

 

 

 

 

2

(TRX -)

6

(RCV -)

 

 

 

 

3

(RCV +)

1

(TRX +)

 

 

 

 

6

(RCV -)

2

(TRX -)

 

 

4, 5, 7, 8

Not Used

 

 

 

 

Table B-3. Crossover Wiring

Kingston Technology Company

KNE24TP/RS User’s Guide - Rev. A01

Page 22
Image 22
Kingston Technology KNE24TP/RS, KNE16TP/RS manual Appendix B Cabling Guidelines, Cable Types, UTP Cable Wiring