7. Plug into a grounded 3 prong outlet.
Electronic Ignition System

Initial lighting and gas flame adjustments

Cooktop and oven burners use electronic igniters in place of
standing pilots. When the cooktop control knob is turned to the
“LITE” position, the system creates a spark to light the burner.
This sparking continues, as long as the control knob is turned to
“LITE.”
When the oven control is turned to the desired setting, sparking
occurs and ignites the gas.

Check Operation of Cooktop Burners

Standard Surface Burners

Push in and turn each control knob to the “LITE” position.
The flame should light within 4 seconds. The first time a burner is
lit it may take longer that 4 seconds to light because of air in the
gas line.

TripleTier® Flame Burner

To start simmer burner:
Push in and turn control knob to “LITE” to start the inner burner.
The flame should light within 4 seconds. The first time a burner is
lit it may take longer that 4 seconds to light because of air in the
gas line.
To start power burner:
Push in control knob again and turn to “POWER BURNER HI” to
light the outer burner.
The flame should light within 4 seconds. The first time a burner is
lit it may take longer that 4 seconds to light because of air in the
gas line.

If burners do not light properly:

Turn cooktop control knob to the “OFF” position.
Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.
Check that the gas shutoff valves are set to the “open”
position.
Check that burner caps are properly positioned on burner
bases.
Repeat start-up. If a burner does not light at this point, turn the
control knobs to “Off” and contact your dealer or authorized
service company for assistance.

Adjust Flame Height

Adjust the height of top burner flames. The cooktop “low” burner
flame should be a steady blue flame approximately ¼" (0.64 cm)
high.
To adjust standard burners:
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
If the “low” flame needs to be adjusted:
1. Remove the control knob.
2. Hold the knob stem with a pair of pliers. Use a small flat-
blade screwdriver to turn the screw located in the center of
the control knob stem until the flame is the proper size.
3. Replace the control knob.
4. Test the flame by turning the control from “LO” to “HI,”
checking the flame at each setting.
To adjust TripleTier® Flame burner:
1. Remove the control knob.
2. Insert a flat-blade screwdriver into adjustment locations
shown in the following illustration and engage the slotted
screw. Turn the screw until the flame is the proper size.
3. Replace the control knob.
4. Test the flame by turning the control from “LO” to “HI,”
checking the flame at each setting.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A.Low flame
B.High flame
A.Valve stem
A.Simmer burner regulation
B.Power burner regulation
A
B
A
A
B