20
IMPORTANT: The TripleTier® Flame burner has 2 gas orifice
spuds. Do not forget to change the external gas orifice spud
located under the plate.
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
5. Use a 7 mm combination wrench to remove the external
orifice spud. Turn counterclockwise to remove. Set external
gas orifice spud aside.
6. Replace each LP gas orifice spud with the correct Natural gas
orifice spud. Refer to the following chart for correct Natural
gas orifice spud placement.
Natural Gas Orifice Spud Chart for TripleTier® Flame Burners
7. Replace burner plate, head and cap.
8. Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
To Convert Oven Bake Burner
1. Remove oven racks.
2. Use a ½" combination wrench to loosen the orifice hood
away from the pin (about 2 to 2½ turns). The oven bake
burner flame cannot be properly adjusted if this conversion is
not made. See “Adjust Oven Bake Burner Flame” in the
“Electronic Ignition System” section.
To Convert Oven Broil Burner
1. Use a ½" combination wrench to loosen the orifice hood
away from the pin (about 2 to 2½ turns). The oven broil burner
flame cannot be properly adjusted if this conversion is not
made. See “Adjust Oven Broil Burner Flame” in the
“Electronic Ignition System” section.
2. Reinstall the warming or storage drawer. See the “Replace
Oven Racks and Warming or Storage Drawer” section for
instructions.
3. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner and oven bake burner
flame is very important. Natural gas flames do not have
yellow tips.
IMPORTANT: You may have to adjust “LO” setting for each
cooktop burner.
A.Plate
B.External gas orfice spud
C.Internal gas orifice spud
Burner Location Burner Rating Size
Left front (external
Tripl eTie r® burner) 12,200 Btu/h 1.70 mm
Left front (internal
Tripl eTie r® burner) 2,800 Btu/h 0.70 mm
A
B
C
A.Orifice hood
B.Pin
A.Locking screw
B.Orifice hood
A
B
A
A
AB