5. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown. (To disconnect, turn off the gas
supply to the 20lb LP gas fuel tank, then unscrew the gas
pressure regulator/hose assembly from the 20lb LP gas fuel
tank as shown.)
6. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
7. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
8. Slide tank tray back into the cabinet.
9. Go to “Plug in Side Burner” in this section.
Gas Connection to Natural Gas or Local LP Gas
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
side burner to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the side burner to the rigid gas
supply line. A ⁵⁄₈" diameter line is recommended. Using a
wrench to tighten, connect the gas supply to the side
burner. Use pipe-joint compound on all non-flared male
threads. Do not kink or damage the flexible connector
when moving the side burner.
Pipe-joint compounds suitable for use with LP gas must
be used. Do not use TEFLON®† tape.
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
Plug in Side Burner
NOTE: This built-in outdoor side burner comes with a large
2,085mAmp power transformer/plug assembly for the side
burner igniters. Follow the instructions for plugging in and
mounting the power transformer. Keep any electrical supply cord
away from any heated surfaces.
A.20 lb LP gas fuel tank
B.Gas pressure regulator/hose assembly
A
B

connect

disconnect

WARNING
Explosion Hazard

Use a new CSA International approved “outdoor”

gas supply line.
Securely tighten all gas connections.

If connected to LP, have a qualified person make sure

gas pressure does not exceed 11” (28 cm) water

column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A.New CSA International approved
“outdoor” flexible gas supply line
B.Rear of side burner
C.To Natural gas or Local LP gas supply
A.Closed valve
B.Open valve
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
B
C
A
A
B