22
Form bare ground wire into a U-shaped hook. Wrap
ground wire hook clockwise around ground connector
screw and under the washer. Securely tighten ground
connector.
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Ground
wire
Direct WireConnectground wire
2
Ground
wire
Washer
Ground
connector
Terminal box wire:
white
black
ground connector
Power supply wire:
white
black
ground wire
Wiring configuration
If needed, see website for animated representation
of this step. Visit www.kitchenaid.com/electrical under
FAQ tab.
NOTE: Twist on UL listed or CSA approved wire
connector. Gently tug on wires to be sure both are
secured.
Connect wires black to black and white to white, using
UL listed or CSA approved twist-on wire connectors (not
included).
Direct WireConnectremaining wires
3
Tighten strain relief screws to secure cable.
Direct WireSecure cable in strain relief
4
Place wires inside terminal box. Insert tabs on left side
of cover. Make sure wires are tucked inside box. Close
cover ensuring wires are not pinched. Use 1/4 nut
driver and previously removed screw to secure cover.
Direct WireReinstallterminal box cover
5