KitchenAid W10117506B installation instructions Electrical Requirements, Recommended Ground Method

Models: W10117506B

1 24
Download 24 pages 41.95 Kb
Page 6
Image 6

NOTE: The outdoor sear burner drops into the enclosure opening and is supported by its side flanges. No bottom support is needed.

Electrical Requirements

A

BC

D

WARNING

Electrical Shock Hazard

E F

G

H

 

A. 12" (30.5 cm) minimum to sear

E. 7¹⁄₈" (18.1 cm)

burner or any accessory

F. Gas line location at rear of

B. 13¹⁄₂" (34.3 cm)

sear burner

C. 22¹¹⁄₁₆" (57.6 cm)

G. 10⁵⁄₈" (27.0 cm)

D. 2¹⁄₄" (5.7 cm)

H. 35¹⁄₂" (90.2 cm)

Built-in Outdoor Sear Burner Enclosure Ventilation for LP Gas:

An enclosure for an LP gas fuel tank is to be ventilated by openings at both the top and lower levels of the enclosure.

If converting to LP gas these vents are to be in the enclosure:

An enclosure for use with an LP gas fuel tank for built-in installation is to have at least one ventilation opening on an exposed exterior side located within 5" (12.7 cm) of the top and is to be a minimum of 20 in.2 (129.0 cm2). One ventilation opening within 1" (2.5 cm) of the bottom of the enclosure and the bottom opening is to be a minimum of 10 in.2 (64.5 cm2). All vent openings are to be unobstructed. Every opening is to be a minimum of ¹⁄₈" (0.32 cm) wide.

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Check with a qualified electrician if you are not sure whether the infrared sear burner is properly grounded.

A120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is required.

It is recommended that a separate circuit servicing only this sear burner be provided.

The model/serial number rating plate is located on the right-hand side panel. See the following illustration.

A

A. Model/serial number plate

Recommended Ground Method

The outdoor infrared sear burner, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70, or Canadian Electrical Code, CSA C22.1.

Copies of the standards listed above may be obtained from:

CSA International

20 in.2 (129.0 cm2) min. ventilation both sides

1" (2.5 cm) max.

10 in.2 (64.5 cm2) min. ventilation both sides

5" (12.7 cm) max.

8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575

National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

B

A

5" (12.7 cm) max.

C

A. 3 prong ground plug

B. 3-prong polarized type outdoor outlet

C. Ground prong

6