NOTE: The outdoor sear burner drops into the enclosure opening and is supported by its side flanges. No bottom support is needed.
Electrical Requirements
A
BC
D
WARNING
Electrical Shock Hazard
E F
G | H |
|
A. 12" (30.5 cm) minimum to sear | E. 7¹⁄₈" (18.1 cm) |
burner or any accessory | F. Gas line location at rear of |
B. 13¹⁄₂" (34.3 cm) | sear burner |
C. 22¹¹⁄₁₆" (57.6 cm) | G. 10⁵⁄₈" (27.0 cm) |
D. 2¹⁄₄" (5.7 cm) | H. 35¹⁄₂" (90.2 cm) |
An enclosure for an LP gas fuel tank is to be ventilated by openings at both the top and lower levels of the enclosure.
If converting to LP gas these vents are to be in the enclosure:
An enclosure for use with an LP gas fuel tank for
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Check with a qualified electrician if you are not sure whether the infrared sear burner is properly grounded.
A
It is recommended that a separate circuit servicing only this sear burner be provided.
The model/serial number rating plate is located on the
A
A. Model/serial number plate
Recommended Ground Method
The outdoor infrared sear burner, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70, or Canadian Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International
20 in.2 (129.0 cm2) min. ventilation both sides
1" (2.5 cm) max.
10 in.2 (64.5 cm2) min. ventilation both sides
5" (12.7 cm) max.
8501 East Pleasant Valley Rd. Cleveland, Ohio
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
B
A
5" (12.7 cm) max.
C
A. 3 prong ground plug
B.
C. Ground prong
6