KitchenAid W10267109C Installation Requirements, ToolsandParts, Location Requirements

Models: W10267109C

1 36
Download 36 pages 47.23 Kb
Page 5
Image 5
INSTALLATION REQUIREMENTS

INSTALLATION REQUIREMENTS

ToolsandParts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Level

Drill

1¹⁄₄" drill bit

³⁄₈" (8 mm) nut driver or ratchet

Pencil

Pliers

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Phillips screwdriver

Flat-blade screwdriver

Saber or keyhole saw

Vent clamps

Metal snips

Parts needed

Home power supply cable

Two ¹⁄₂" (12.7 mm) UL listed or CSA approved strain reliefs

For vented installations, you will also needed:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also need:

Recirculation Kit Part Number 4396565. See “Assistance or Service” section to order.

Optional parts needed:

Wood filler strips for cabinets with recessed bottoms. Length and thickness determined by recess dimensions. See “Prepare Location” section.

Two, 1" x 1" x 5" (25.4 x 25.4 x 127 mm) wood pieces for cabinet floor. See “Prepare Location” section.

Four, 1¹⁄₄" (31.8 mm) wood screws

Parts supplied

Remove parts from packages. Check that all parts are included.

2 screws (used for mounting the vent grate)

Damper

Plastic cover (used for customized front trim)

Hardware package

Vent grate (for non-vented/recirculating installations)

Front trim - White (installed), Black, and Brushed Aluminum

Gray vinyl strip (used for bottom of cabinet, rear trim and 3 mounting screws)

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the range hood.

Range hood location should be away from strong draft areas, such as windows, doors, and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult your cooktop/ range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The range hood is factory set for vented installations through the roof or wall. For non-vented (recirculating) installations see “Non- Vented (recirculating) Installation Through the Soffit/Cabinet” in the “Prepare Location” section. Recirculation Kit Part Number 4396565 is available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where range hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.

5

Page 5
Image 5
KitchenAid W10267109C Installation Requirements, ToolsandParts, Location Requirements, Tools needed, Parts needed