Image 8
ElectricalRequirements

ElectricalRequirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

PrepareLocation

It is recommended that the vent system be installed before the range hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for vent fittings.

1.Disconnect power.

2.Determine which venting method to use: roof, wall, or non- vented.

3.Select a flat surface for assembling the range hood. Place covering over that surface.

INSTALLATION INSTRUCTIONSWARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.

4.Using 2 or more people, lift range hood onto covered surface.

Range Hood Cabinet Cutout

1.Determine and clearly mark a centerline on the underside of the cabinet.

A

A.Centerline

2.Measure and mark lines as shown for your size of range hood. Use a saber saw or keyhole saw to cut an opening through the underside of the cabinet.

1³⁄₈"

(3.5 cm)

9¹³⁄₁₆"

(24.9 cm)

30" (76.2 cm) hood - 12⁵⁄₈" (32.0 cm) 36" (91.4 cm) hood - 15⁵⁄₈" (39.7 cm)

The finished cutout size will be:

30" (76.2 cm) range hood - 9¹³⁄₁₆" x 25¼" (24.9 cm x 64.1 cm) 36" (91.4 cm) range hood - 9¹³⁄₁₆" x 31¼" (24.9 cm x 79.3 cm)

8

Page 8
Image 8
KitchenAid W10267109C Installation Instructions, ElectricalRequirements, PrepareLocation, Range Hood Cabinet Cutout